The AirTAC GFC Combination Unit GFC200C08F1K is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC200C08F1K is the two-unit G-series set - filter regulator plus lubricator - with a reverse (check) valve fitted, so downstream pressure is held if the upstream supply is lost or dropped. This 200-size configuration has PT1/4 ports, the standard 40 um filter element, a differential-pressure drain on the filter bowl and the embedded square gauge with MPa scale. The regulator adjusts from 0.15 to 0.9 MPa (20 to 130 psi) with this drain type, and the polycarbonate bowls suit the -5 to 70 C operating range.
This is a genuine AirTAC part, one of the G series sizes 200/300/400/600 with ports from 1/8 to 1 inch and PT, G or NPT thread options. Flow is published as curves, not a single rating, so ask us to confirm the datasheet and flow figures for this code on request.
| Model | Airtac GFC Combination Unit GFC200C08F1K |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · See datasheet · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-C0 |
| Build order | Filter regulator first, lubricator last |
Supplies the fixture clamps around a robotic weld cell, with the check valve holding clamp pressure if the plant air main dips mid-cycle.
Feeds the solenoid manifold on a machine control panel, filtering supply air, regulating branch pressure and mist-lubricating the actuator circuits downstream.
Prepares air for the part-blowoff and ejection cylinders beside a press, where the check valve keeps the ejection circuit charged between strokes.
Choose this code over GFC200C08F1 when you want the K-option check valve in the set; drop the K if your circuit handles back-flow itself. The 200 size and 1/4 in PT ports are the small end of the range - step to 300, 400 or 600 for heavier demand. Filtration here is the standard 40 um grade; add W for 5 um. The F1 suffix is the embedded square gauge with MPa scale; psi or bar scales or an external round gauge are alternatives. Drain is the differential-pressure default, with automatic (A) or manual (M) options - a manual drain widens the regulating range to 0.05-0.9 MPa (7-130 psi). PT thread is standard; G (BSPP) and NPT are catalogue options to order.
Flow for the G series appears only as datasheet curves, so ask us to confirm sizing against your application before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.
AirTAC publishes flow for the G series as characteristic curves rather than a single rated figure or Cv value, so we do not quote one number. Share your air demand and we will confirm the relevant datasheet figures for this exact code on request so you can size it correctly.
The K suffix fits a reverse (check) valve in the set, which holds downstream pressure if the upstream supply fails or is shut off - useful for clamps or vertical cylinders that must not lose position. The same set without the K code simply passes air in both directions.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.