The AirTAC GFC Combination Unit GFC200C08MC1 is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC series pairs a filter-regulator with a separate lubricator in one two-unit set, covering clean air, stable pressure and oil-mist lubrication for downstream equipment. This 200-size set is ported PT1/4 (PT thread, 1/4 in.). Its manual drain (M) empties the bowl when an operator opens the drain by hand, which suits points checked during routine rounds. The standard 40 um element removes water and particulate, and the C1 gauge is the external round type reading in MPa. Maximum working pressure is 1.0 MPa (145 psi), the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi) on this manual-drain version, and the set is rated for -5 to 70 C. The filter and lubricator bowls on the 200 size are polycarbonate.
This is a genuine AirTAC part. The G series runs from 200 through 600 sizes with ports from 1/8 to 1 in., and offers automatic, manual or differential-pressure drains, 40 or 5 um elements, round or square gauges in MPa, psi or bar scales, a reverse-valve option, and G (BSPP) or NPT threads besides the PT standard. Flow for the series is published as curves rather than a single rated figure, so we confirm the datasheet figures for your application on request.
| Model | Airtac GFC Combination Unit GFC200C08MC1 |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · See datasheet · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-C0 |
| Build order | Filter regulator first, lubricator last |
Filter, regulate and oil the branch line feeding pneumatic nailers and staplers at a woodworking bench; the manual drain suits a shop where the bowl is emptied at the end of each shift.
Keep pusher and reject cylinders on a bottling conveyor supplied with clean, regulated, lubricated air so stroke timing stays consistent across the run.
Condition the air feeding a pick-and-place robot's gripper circuit; the round MPa gauge makes the set-point easy to verify during preventive-maintenance rounds.
The 200 size and its 1/4 in. port suit compact circuits; step to 300, 400 or 600 as port size and flow requirements grow. This set uses the manual drain (M) - choose the automatic (A) or differential-pressure drain when condensate must leave without operator attention. The element here is the standard 40 um grade; the W code gives 5 um. The gauge is the external round type on an MPa scale, with psi (2) and bar (3) scales as options. Thread is PT as standard, and G (BSPP) or NPT can be ordered. Because flow is published as curves rather than a single rating, ask us to confirm sizing for your line before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.
AirTAC publishes flow for the G series as performance curves, not a single rated number, so there is no one figure we can honestly quote. Send us your application details and we will confirm sizing from the datasheet on request.
The manual drain (M) discharges condensate only when an operator opens it, which suits stations checked on a routine schedule. The automatic drain (A) ejects condensate on its own, and the differential-pressure drain (default) discharges as the pressure drop across the filter element builds. All three are catalogue drain choices within the GFC range.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.