The AirTAC GFC Combination Unit GFC200C08MN is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC200C08MN is a genuine AirTAC G-series two-unit F.R.L. set for compressed air: a filter-regulator plus a separate lubricator in one matched pair. This 200-size configuration has PT1/4 ports, a manual drain on the filter bowl and the standard 40 um filter element; the N suffix means no pressure gauge is fitted, so the regulator is set by feel or by a gauge added elsewhere on the line. It filters water and particulate, holds your set downstream pressure and adds oil mist for lubricated equipment.
This is a genuine AirTAC part. The G-series spans 200, 300, 400 and 600 sizes with 1/8 in to 1 in ports, and drain type, filter grade, gauge and valve options vary by code. Max working pressure is 1.0 MPa (145 psi), the temperature range is -5 to 70 C (non-freezing), and the 200-size bowls are polycarbonate. Flow is published as curves rather than a single rated figure, so we confirm datasheet numbers on request.
| Model | Airtac GFC Combination Unit GFC200C08MN |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · See datasheet · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-C0 |
| Build order | Filter regulator first, lubricator last |
A wall-mounted drop at a maintenance bench feeds filtered, regulated, oil-misted air to impact wrenches and ratchets used across the shop.
Prepares the air supply for pusher and stopper cylinders on a bottling conveyor, with manual bowl draining done during scheduled line cleaning.
Serves small actuator circuits inside a control panel build where pressure is read on a panel gauge rather than on the unit itself.
Choose the 200 size with PT1/4 ports when your port step and air demand sit at the small end of the G-series; move to 300, 400 or 600 for bigger ports. The M drain is manual, so bowls are emptied by hand - with manual drainage the regulator adjusts from 0.05-0.9 MPa (7-130 psi); automatic or differential-pressure drain versions adjust from 0.15-0.9 MPa (20-130 psi). This code keeps the standard 40 um element and omits the gauge (N); add an external round gauge or pick an F-code variant if you want visual pressure reference. Thread is PT as standard; G (BSPP) and NPT are catalogue options to order. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.
AirTAC publishes flow for this set as curves across the pressure range rather than a single rated figure, so we do not quote one number out of context. Tell us your operating pressure and air demand and we will confirm the datasheet flow figures for this model on request.
N means no pressure gauge is supplied with this set. The regulator still adjusts from 0.05-0.9 MPa (7-130 psi) with the manual drain, and you can read pressure on a gauge elsewhere in the circuit. If you want a gauge on the unit, the F1-coded variants add the embedded square gauge with an MPa scale.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.