The AirTAC GFC Combination Unit GFC200C08MNK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC200C08MNK is a genuine AirTAC G-series two-unit F.R.L. set for compressed air: a filter-regulator plus a separate lubricator in one matched pair. This 200-size configuration has PT1/4 ports, a manual drain on the filter bowl and the standard 40 um filter element, with no gauge (N) and a reverse (check) valve fitted (K). It filters water and particulate, holds your set downstream pressure, meters oil mist into the line, and the check valve prevents backflow through the unit.
This is a genuine AirTAC part. The G-series spans 200, 300, 400 and 600 sizes with 1/8 in to 1 in ports, and drain type, filter grade, gauge and valve options vary by code. Max working pressure is 1.0 MPa (145 psi), the temperature range is -5 to 70 C (non-freezing), and the 200-size bowls are polycarbonate. Flow is published as curves rather than a single rated figure, so we confirm datasheet numbers on request.
| Model | Airtac GFC Combination Unit GFC200C08MNK |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · See datasheet · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-C0 |
| Build order | Filter regulator first, lubricator last |
Feeds a pilot-air circuit where backflow through the prep unit must be prevented, with the K-suffix check valve handling that role.
Supplies filtered, regulated, lubricated air to forming and punching stations on a production floor, with manual bowl draining at shift checks.
Prepares air for pallet-door and dock equipment cylinders in a warehouse, keeping lubricated tools and actuators supplied from one point.
This code suits 1/4 in circuits where you also want the reverse (check) valve fitted, for example ahead of a circuit that must not push air back through the prep unit. At 200 size, step to 300, 400 or 600 if larger ports or flow are required. The M drain is manual - with manual drainage the regulator adjusts from 0.05-0.9 MPa (7-130 psi); automatic or differential-pressure drain versions adjust from 0.15-0.9 MPa (20-130 psi). The element is the standard 40 um; pick a W-code variant for the 5 um element, and an F1-code variant if you need the embedded square MPa gauge. Thread is PT as standard; G (BSPP) and NPT are catalogue options to order. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.
There is no single rated flow figure to quote: AirTAC publishes flow for this set as curves across the pressure range. Share your line pressure and air consumption and we will confirm the flow and datasheet figures for this exact model on request.
K means a reverse (check) valve is fitted, so air cannot flow backwards through the unit; the plain code has none. Everything else matches: 1/4 in PT ports, manual drain, standard 40 um element and no gauge. If you also want fine filtration, the W-coded variant carries the 5 um element.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.