The AirTAC GFC Combination Unit GFC200C08NW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC series is a two-piece set combining a filter-regulator with a lubricator, so one station filters, regulates and lubricates the compressed air feed. This GFC200C08NW is the size 200 frame with 1/4 inch PT ports, the default differential-pressure drain and the finer 5 um filter element; it is ordered without a gauge and without a check valve.
This is a genuine AirTAC part. Maximum working pressure is 1.0 MPa (145 psi), the temperature range is -5 to 70 C, and the bowls on the size 200 frame are polycarbonate. With the differential-pressure drain, the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi). The series spans sizes 200 to 600 with ports from 1/8 to 1 inch, plus drain, gauge, check valve and G/NPT thread variants; flow figures are published as curves, so we confirm the datasheet on request.
| Model | Airtac GFC Combination Unit GFC200C08NW |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · See datasheet · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-C0 |
| Build order | Filter regulator first, lubricator last |
Machining centres with pneumatic tool clamping and chip-blast functions are sensitive to fine particulate; the 5 um element in this set conditions the machine's dedicated 1/4 inch air feed.
Workshop drop points feeding die grinders and needle scalers get filtered, regulated, lubricated air from this set, with the finer element helping precision air tools run cleanly.
High-cycle diverter and pusher cylinders on sorting conveyors are fed from this conditioning set, keeping moisture and grit out of the valve island while the lubricator mists the cylinders.
Pick the W code when the 5 um element is what your downstream valves and tools want; the 40 um standard grade remains available if coarse filtration is enough. Size 200 with the 1/4 inch port suits machine and bench drops, stepping to 300, 400 or 600 as demand rises. The differential-pressure drain is the catalogue default, with automatic and manual drain variants for other duties. Gauges in MPa, psi or bar scale and G or NPT threads are orderable options.
Flow is published as curves, not a single rated figure, so send your air demand and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.
AirTAC publishes GFC flow as curves across pressure and size, not as a single rated figure, so no flow number appears here. Send us your consumption and working pressure and we will confirm whether size 200 at 1/4 inch is correct, checking the datasheet on request.
The W in the code selects the 5 um element, the finer of the two catalogue grades, suited to airlines feeding precision valves, air tools and instruments. The standard grade is 40 um for general plant air; choosing finer filtration with a differential-pressure drain keeps the regulator range at 0.15-0.9 MPa (20-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.