AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac GFC Combination Unit GFC300C08AC1W

The AirTAC GFC Combination Unit GFC300C08AC1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$89.04 $94.93Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC300-08 drain, gauge and thread option on one page All GFC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFC Combination Unit GFC300C08AC1W

GFC300C08AC1W is a genuine AirTAC G-series two-unit combination: a GFR300 filter-regulator paired with a GL300 lubricator, so it filters water and particulate out of the air, regulates downstream pressure and adds oil mist for downstream tools in one 1/4 in (PT1/4) connection. This configuration has an automatic drain on the filter bowl, a 5 um (W) filter element instead of the 40 um standard, and a round external pressure gauge reading in MPa. Maximum inlet pressure is 1.0 MPa (145 psi) and, with the automatic drain, the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi). It runs on compressed air only, from -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GFC two-unit family is available in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in, 40 um standard or 5 um (W) filtration, automatic, manual or differential-pressure drains, round or square gauges in MPa, psi or bar scales, and PT, G or NPT threads. Flow figures for the G series are published as curves rather than a single rating, so ask us and we will confirm the datasheet for this exact model on request.

Airtac GFC Combination Unit GFC300C08AC1W Technical Specifications

ModelAirtac GFC Combination Unit GFC300C08AC1W
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFC Combination Unit GFC300C08AC1W

GFC300G-series two-unit set, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C0 filter regulator and GL300-C0 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C0
Build orderFilter regulator first, lubricator last

Where the Airtac GFC Combination Unit GFC300C08AC1W Is Used

factory

Packaging line pick-and-place supply

Conditioning the air feeding the vacuum and clamp cylinders on a carton-forming line: the 5 um element protects the valve stack, the regulator holds consistent cylinder force, and the lubricator keeps the actuator seals working shift after shift while the automatic drain clears condensate without stopping the line.

precision_manufacturing

Pneumatic press and clamping fixtures

Supplying filtered, regulated and lubricated air to the clamping fixtures on a small pneumatic press, where the MPa gauge lets the setter set and verify clamping pressure directly and the automatic drain suits a fixture mounted where daily bowl draining is impractical.

settings_input_component

Automated assembly cell air preparation

Serving as the single air-preparation point for a rotary indexing assembly cell: one 1/4 in PT connection upstream of the manifold feeds every cylinder and air tool with clean, regulated, oil-misted air, with the 5 um grade chosen to shield the fine-control valves in the cell.

Is the Airtac GFC Combination Unit GFC300C08AC1W the Right Set?

Match the size to the air demand and piping: this 300-size set connects at PT1/4 (1/4 in), while the GFC family steps from size 200 at 1/8 in up to size 600 at 1 in as flow requirement rises. This unit has an automatic drain, which suits unattended or hard-to-reach installations; manual-drain and differential-pressure-drain versions exist at the same size. The 5 um (W) element gives finer filtration than the 40 um standard, which matters for sensitive valves and cylinders. The gauge here is the round external type in MPa; square-gauge (F) versions and psi or bar scales are also in the family. The 300-size bowls are polycarbonate (PC), and the operating range is -5 to 70 C.

Thread is PT as standard; G (BSPP) and NPT are catalogue options to order. AirTAC publishes flow for the G series as curves, not a single rated figure, so send us your working pressure and air demand and we will confirm sizing against the curve before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C0 filter regulator on its own.

Airtac GFC Combination Unit GFC300C08AC1W FAQ

AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not quote a number on the page. Tell us your working pressure and air demand and we will confirm the flow curve and full datasheet for this exact model on request before you order.

W is the filter-grade code: this set carries the 5 um element instead of the 40 um standard. Choose 5 um when the downstream valves, cylinders or instruments are sensitive to fine particulate; choose the standard 40 um grade for general shop-air duty where finer filtration is not required.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFC Combination Unit GFC300C08AC1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC300C08AC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.