The AirTAC GFC Combination Unit GFC300C08AF1WK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC two-unit set combines a filter regulator and a lubricator, giving filtered, regulated and oil-mist-lubricated air from one 1/4 in PT connection. This version is fitted with a reverse (check) valve so flow through the set cannot run backwards, and it carries the fine 5 um element, an automatic drain, a standard-type regulator and an embedded square gauge scaled in MPa.
This is a genuine AirTAC part. Maximum inlet pressure is 1.0 MPa (145 psi), the working temperature range is -5 to 70 C (non-freezing), and at size 300 the bowls are polycarbonate. The family spans sizes 200 to 600 with alternative drains, thread options and a no-check-valve variant; we confirm flow and datasheet figures on request.
| Model | Airtac GFC Combination Unit GFC300C08AF1WK |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C0 filter regulator and GL300-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · See datasheet · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-C0 |
| Build order | Filter regulator first, lubricator last |
Feeds the swing clamps on a machining fixture; the fitted check valve blocks reverse flow through the set, the regulator holds the clamp circuit pressure, and the lubricator conditions the clamp's air side.
Conditions supply air for a laboratory leak-test or pressure-test bench: the 5 um element keeps the test circuit clean ahead of the regulator, and the square MPa gauge gives a direct pressure readout.
Regulates and lubricates the air supply to quarter-turn actuators on a small valve skid; the check valve prevents backflow through the set when an upstream branch is isolated.
This code selects the 5 um element (W), the automatic drain (A), the embedded square MPa gauge (F1) and the reverse/check valve (K); the same set without the check valve is GFC300C08AF1W. With automatic or differential-pressure drain the regulator adjusts 0.15-0.9 MPa (20-130 psi); manual-drain variants in the family widen that to 0.05-0.9 MPa (7-130 psi). Size 300 gives a 1/4 in port; sizes 400 and 600 step up the port for heavier lines. PT is the standard thread, with G (BSPP) and NPT as catalogue thread options. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C0 filter regulator on its own.
AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and demand and we will confirm the sizing from the datasheet on request.
K means a reverse (check) valve is fitted, so flow through the set cannot run backwards. The identical set without the check valve is ordered as GFC300C08AF1W.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.