The AirTAC GFC Combination Unit GFC300C08F1 is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The GFC series is AirTAC's two-unit air-treatment set: a filter regulator paired with a lubricator, providing filtration, pressure regulation and oil-mist lubrication from a single set. This GFC300C08F1 is the size 300 body on a PT1/4 port. The filter bowl uses the differential-pressure drain (the default) with the standard 40 um element, and the regulator carries the embedded square pressure gauge with MPa scale, adjusting between 0.15-0.9 MPa (20-130 psi). It is for compressed air only, rated to 1.0 MPa (145 psi) inlet and -5 to 70 C.
This is a genuine AirTAC part. The G series is offered in sizes 200, 300, 400 and 600 with ports from 1/8 inch to 1 inch, and drain type, filter grade, gauge style and scale, and thread form (PT as standard, with G and NPT as catalogue options) are selectable. AirTAC publishes flow as characteristic curves rather than a single rated figure, so we confirm flow and other datasheet numbers on request.
| Model | Airtac GFC Combination Unit GFC300C08F1 |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C0 filter regulator and GL300-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · See datasheet · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-C0 |
| Build order | Filter regulator first, lubricator last |
Feeding impact drivers, nutrunners and air ratchets at an assembly workbench: the set cleans and regulates the 1/4 inch drop and mists oil to the tool motors through their quick couplings.
Conditioning the air at a takeoff from a factory ring main: one two-unit set gives the branch its own 40 um filtration, a set line pressure on the square gauge, and lubrication for the tools and cylinders on that drop.
Supplying the divert and stopper cylinders along a parcel or tote conveyor line, where the regulator holds the set pressure for consistent actuation and the lubricator feeds the cylinder seals.
Size 300 on a PT1/4 port suits 1/4 inch branches serving downstream cylinders, valves and air tools; the same set is available in size 400 or 600 on larger ports if demand grows. This version keeps the standard 40 um element - choose the W suffix instead if the downstream equipment needs 5 um filtration.
Drain is the differential-pressure default, with automatic and manual drain options; a manual-drain version widens the regulator's lower adjustment limit to 0.05 MPa. The regulation range on this differential-drain set is 0.15-0.9 MPa (20-130 psi), read on the embedded square MPa gauge; a round gauge, or a square gauge in psi or bar scale, can be ordered. Thread is PT as standard, with G (BSPP) and NPT as orderable options. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C0 filter regulator on its own.
AirTAC publishes flow for the G series as characteristic curves rather than a single rated figure, so we do not quote a rated flow here. Share your line pressure, downstream consumption and allowable pressure drop, and we will confirm the correct size and the curve data from the datasheet on request.
The F in this code selects the embedded square gauge with MPa scale (1). A round gauge is the alternative (code C), and scales of psi (2) or bar (3) are also available. So GFC300C08F1 is square/MPa, while GFC300C08C1 would be round/MPa - the treatment function is otherwise the same.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.