The AirTAC GFC Combination Unit GFC300C08F1WK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$89.95 $95.87Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC300-08 drain, gauge and thread option on one page All GFC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFC Combination Unit GFC300C08F1WK

The AirTAC GFC series is a two-unit air preparation set: a filter-regulator plus a lubricator, so one model filters, regulates and lubricates compressed air. This GFC300C08F1WK is size 300 with PT1/4 ports, fitted with the fine 5 um (W) filter element, a square embedded MPa gauge, the standard differential-pressure drain, and a reverse (check) valve that lets downstream pressure hold when the upstream supply is removed.

This is a genuine AirTAC part. The GFC family comes in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, in PT, G (BSPP) or NPT thread, with 40 um or 5 um filtration, automatic, manual or differential-pressure drains, and optional external round gauges. Flow is published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application.

Airtac GFC Combination Unit GFC300C08F1WK Technical Specifications

ModelAirtac GFC Combination Unit GFC300C08F1WK
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFC Combination Unit GFC300C08F1WK

GFC300G-series two-unit set, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C0 filter regulator and GL300-C0 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C0
Build orderFilter regulator first, lubricator last

Where the Airtac GFC Combination Unit GFC300C08F1WK Is Used

valve

Clamping circuit with retained pressure

On a pneumatic clamping fixture, the fitted check valve holds downstream pressure if the upstream supply drops, while the set filters, regulates and lubricates the air feeding the clamp cylinders.

conveyor_belt

Conveyor diverters and stoppers

Prepares air for stop-and-go cylinders and pop-up diverters on a conveyor line; the 5 um element protects solenoid valves and the lubricator mists oil to the actuator seals.

build

Pneumatic gripper cells

Feeds gripper and tool-changer circuits on a robotic cell, with regulated pressure read on the MPa gauge and the check valve helping preserve grip pressure through supply interruptions.

Is the Airtac GFC Combination Unit GFC300C08F1WK the Right Set?

Size 300 with 1/4 inch PT ports suits compact machine supply points; size up or down (200-600) to match air demand. The K code here means a reverse/check valve is fitted - specify it whenever trapped downstream pressure should be retained or backflow prevented. This unit has the 5 um (W) element and a square MPa gauge; a round external gauge on MPa, psi or bar scale is optional, and thread is PT, G or NPT at order.

Because AirTAC publishes flow as performance curves and not as one rated number, we cannot quote a flow figure here. Send us your application and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C0 filter regulator on its own.

Airtac GFC Combination Unit GFC300C08F1WK FAQ

AirTAC publishes flow for the G series as performance curves, not as a single rated figure, so no honest single number can be quoted here. Tell us your line pressure and air demand and we will confirm the datasheet curve for this exact 1/4 inch set before you order.

K means a reverse (check) valve is fitted in this filter-regulator, so downstream pressure is held against backflow when the upstream supply is lost - useful for clamps, grippers and any load that must not release. Apart from the valve, the set is identical to GFC300C08F1W: PT1/4 ports, 5 um filtration, differential-pressure drain, square MPa gauge.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFC Combination Unit GFC300C08F1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC300C08F1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.