verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac GFC Combination Unit GFC300C08NK

The AirTAC GFC Combination Unit GFC300C08NK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$84.30 $90.07Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC300-08 drain, gauge and thread option on one page All GFC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFC Combination Unit GFC300C08NK

The AirTAC GFC series is a two-unit air preparation set: a filter-regulator and a lubricator mounted together as one assembly. GFC300C08NK is the 300 size with PT1/4 ports, the standard 40 um filter element, a differential-pressure drain, no gauge, and a reverse (check) valve fitted - the K in the code - so reverse flow through the set is blocked. It removes water and particulate, holds the downstream pressure you set - adjustable from 0.15 to 0.9 MPa (20 to 130 psi) on this differential-drain version - and meters oil mist to the equipment behind it. Max inlet pressure is 1.0 MPa (145 psi), temperature range is -5 to 70 C, and the 300-size bowls are PC (polycarbonate).

This is a genuine AirTAC part. The G series spans 200, 300, 400 and 600 sizes with ports from 1/8 in. to 1 in., and drain type, filter grade, gauge, reverse-valve and G/NPT thread variants are catalogue choices. AirTAC publishes flow for these units as curves rather than a single rated figure, so ask us and we will confirm the flow and datasheet figures before you order.

Airtac GFC Combination Unit GFC300C08NK Technical Specifications

ModelAirtac GFC Combination Unit GFC300C08NK
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFC Combination Unit GFC300C08NK

GFC300G-series two-unit set, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C0 filter regulator and GL300-C0 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C0
Build orderFilter regulator first, lubricator last

Where the Airtac GFC Combination Unit GFC300C08NK Is Used

valve

Clamping fixture circuit

Supplies filtered, regulated, lubricated air to a workholding clamping fixture: the check valve blocks reverse flow back through the set, helping the downstream circuit stay as set while the 40 um element keeps the fixture valves clean.

factory

Robot welding cell gripper air

Conditions the air feeding gripper cylinders and weld-gun clamps in a robot welding cell, with the regulator holding a steady set pressure and the differential-pressure drain keeping condensate off the maintenance routine.

engineering

Equipment rebuild test bench

On a rebuild shop test bench, the set gives technicians clean, regulated, oil-misted air for cycling refurbished cylinders and valves, while the check valve keeps the bench circuit isolated from backflow.

Is the Airtac GFC Combination Unit GFC300C08NK the Right Set?

Size the set by port and flow: G series steps 200, 300, 400 and 600 cover ports from 1/8 in. to 1 in., and this 300 set carries PT1/4 as the standard thread, with G (BSPP) and NPT available to order. The 40 um element is the standard grade, with the W-coded 5 um option for finer prefiltration. The differential-pressure drain avoids a manual drain routine; automatic and manual drain variants exist. The K code adds a reverse (check) valve and N means no gauge; both choices are configurable across the family. Flow is published as curves, not a single rating - ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C0 filter regulator on its own.

Airtac GFC Combination Unit GFC300C08NK FAQ

No single rated flow figure is published for the G series; AirTAC gives flow as performance curves against pressure. Send us your flow requirement and we will confirm the curve data and datasheet figures for this 300-size, PT1/4 set on request before you order.

The K adds a fitted reverse (check) valve, which blocks reverse flow through the set; the non-K version has no check valve. Both share the same 300 size, PT1/4 ports, 40 um element, differential-pressure drain and no-gauge configuration.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFC Combination Unit GFC300C08NK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC300C08NK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.