verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac GFC Combination Unit GFC300C10AC1

The AirTAC GFC Combination Unit GFC300C10AC1 is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$89.04 $94.93Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC300-10 drain, gauge and thread option on one page All GFC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFC Combination Unit GFC300C10AC1

The AirTAC GFC series is a two-piece air preparation set: a filter regulator plus a lubricator ordered as one unit. This 300-size configuration is threaded PT3/8 and filters to the standard 40 um grade, regulates working pressure across 0.15-0.9 MPa (20-130 psi), and lubricates downstream components with an oil mist. The A in the code specifies an automatic drain, which expels collected condensate from the bowl without operator attention, and an external round gauge on the MPa scale is included so operators can read set pressure directly.

This is a genuine AirTAC part. The G series spans sizes 200 to 600, with PT as the standard thread and G(BSPP) or NPT as catalogue options; the regulator can alternatively carry an embedded square gauge, and gauge scales come in MPa, psi or bar. Flow is published as curves rather than a single rated figure, so we confirm datasheet and sizing figures on request.

Airtac GFC Combination Unit GFC300C10AC1 Technical Specifications

ModelAirtac GFC Combination Unit GFC300C10AC1
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFC Combination Unit GFC300C10AC1

GFC300G-series two-unit set, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C1
Build orderFilter regulator first, lubricator last

Where the Airtac GFC Combination Unit GFC300C10AC1 Is Used

factory

CNC machine tool air supply

Conditioning shop air feeding a CNC machining centre's tool-change cylinder and air-blast circuits: the automatic drain copes with condensate from humid shop air, and the MPa gauge lets maintenance read the set pressure at a glance.

local_shipping

Fleet workshop service drops

A PT3/8 drop at a truck and bus service bay feeding impact wrenches and tyre-cage inflating circuits, with the lubricator oiling the tool motors and the regulator holding a steady working pressure.

conveyor_belt

Case-erector carton feed section

Supplying the vacuum generators and flap-folding cylinders on a case-erector's carton feed section, where the automatic drain keeps the bowl clear during long unattended runs.

Is the Airtac GFC Combination Unit GFC300C10AC1 the Right Set?

Key decode choices here: the 3/8 in PT port steps up from 1/4 in for circuits that move more air through the same size-300 body - and because published flow is a curve, step up a size only after checking demand. The automatic drain suits unattended or hard-to-reach mounting; choose manual (M) where you want purge control at shutdown, or the differential-pressure default where cost matters most. This set carries the 40 um standard element (the 5 um W grade is the alternative) and an external round gauge in MPa - psi and bar scales are orderable, as are G(BSPP) and NPT threads.

Send us your application's flow and pressure points and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.

Airtac GFC Combination Unit GFC300C10AC1 FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote a number here. Give us your peak flow and working pressure and we will confirm the size-300, PT3/8 selection against the datasheet on request.

The A in this code specifies an automatic drain, which discharges collected condensate on its own and suits unattended positions or bowls mounted where nobody walks past. The differential-pressure drain is the default and costs-conscious choice; manual (M) gives you deliberate purge control. All three are orderable on the GFC family.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFC Combination Unit GFC300C10AC1

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC300C10AC1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.