The AirTAC GFC Combination Unit GFC300C10AF1WK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$100.39 $106.57Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC300-10 drain, gauge and thread option on one page All GFC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFC Combination Unit GFC300C10AF1WK

The GFC300C10AF1WK is an AirTAC G-series two-unit air preparation set: a filter-regulator plus a separate lubricator in one package, fitted with a reverse (check) valve (K) so air cannot flow back through the set if the upstream supply drops. Air is filtered to the 5 um fine grade (W), downstream pressure is regulated over 0.15-0.9 MPa (20-130 psi) with the automatic drain (A) fitted, and oil mist is metered to the line. The 3/8 in PT port, PC bowls and embedded square gauge with MPa scale complete the configuration.

This is a genuine AirTAC part for compressed air only, rated to 1.0 MPa (145 psi) maximum working pressure and -5 to 70 C, non-freezing. The G series spans sizes 200 to 600 with ports from 1/8 to 1 in, in PT, G (BSPP) and NPT threads, with automatic, manual or differential-pressure drains, 40 or 5 um elements, gauge styles and scales, and the optional K reverse valve fitted here. AirTAC publishes flow as curves rather than a single rating, so we confirm datasheet figures on request.

Airtac GFC Combination Unit GFC300C10AF1WK Technical Specifications

ModelAirtac GFC Combination Unit GFC300C10AF1WK
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFC Combination Unit GFC300C10AF1WK

GFC300G-series two-unit set, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C1
Build orderFilter regulator first, lubricator last

Where the Airtac GFC Combination Unit GFC300C10AF1WK Is Used

bolt

Pneumatic clamp circuits

The built-in check valve helps hold clamp pressure if the upstream supply dips, suiting fixture clamping on a machining or welding line where the clamps must stay engaged.

tune

Paint spray booth

Filtered to 5 um, pressure-regulated and lubricated for spray guns, with reverse-flow protection on the supply drop to the booth.

conveyor_belt

Case-erector stations

Feeds packaging cylinders with filtered, regulated, lubricated air while the check valve stops backflow when upstream valves cycle on a carton-handling conveyor.

Is the Airtac GFC Combination Unit GFC300C10AF1WK the Right Set?

Size 300 with a 3/8 in PT port suits medium-flow branch circuits; step up to 400 or 600 for more flow or down to 200 for compact lines. The K code fits a reverse (check) valve - choose it where a falling upstream supply must not vent the downstream circuit. Drain here is automatic (A); manual (M) or differential-pressure (blank) are alternatives, with manual widening the regulating range down to 0.05 MPa. W selects the 5 um element over the standard 40 um, and F1 gives the embedded square gauge in MPa (round external gauges or N no-gauge are options). Thread is PT as standard; G (BSPP) and NPT are catalogue options. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.

Airtac GFC Combination Unit GFC300C10AF1WK FAQ

AirTAC publishes G-series capacity as flow curves rather than a single rated figure, so we cannot honestly quote one number. Share your working pressure and air demand and we will confirm the curve-based figures and full datasheet for the GFC300C10AF1WK on request.

K fits a reverse (check) valve so air cannot flow back through the set when the upstream supply drops, helping hold downstream pressure. The rest decodes as: 300 size, 10 = 3/8 in PT port, A = automatic drain, F1 = embedded square MPa gauge and W = 5 um element.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFC Combination Unit GFC300C10AF1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC300C10AF1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.