The AirTAC GFC Combination Unit GFC300C10F1 is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC300C10F1 is a two-unit F.R.L. set: a GFR300 filter-regulator plus a GL300 lubricator, giving filtration, regulation and oil-mist lubrication from one order on a 3/8 in PT port. This configuration uses the standard 40 um filter element, a differential-pressure drain on the bowl, and the embedded square pressure gauge scaled in MPa, with standard regulation adjustable from 0.15-0.9 MPa (20-130 psi). Both bowls on this size 300 set are polycarbonate.
This is a genuine AirTAC part. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The G series is also offered in sizes 200, 300, 400 and 600, with manual or automatic drains, a 5 um element option, an external round gauge, G (BSPP) or NPT threads and a reverse/check valve option. Flow is published as curves rather than a single rated figure, so ask us to confirm flow and datasheet details for your application.
| Model | Airtac GFC Combination Unit GFC300C10F1 |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · See datasheet · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-C1 |
| Build order | Filter regulator first, lubricator last |
A standard plant-air drop for hand tools and small cylinders at an assembly bench: filtered, regulated and lubricated from one compact two-unit set.
Feed a bank of solenoid valves and compact actuators in a control panel, with the embedded square gauge readable at the panel face.
Condition the plant air feeding general-purpose lab rigs and jigs where the standard 40 um grade is adequate for the valves in use.
This decode keeps it standard where it counts: size 300, 3/8 in PT port, 40 um element and differential-pressure drain, with the embedded square gauge in MPa instead of the optional round external gauge. Within the same series you can move to the finer 5 um element, choose manual or automatic drainage (each with its own adjust range), switch the gauge scale to psi or bar, or order G (BSPP) or NPT threads. Larger sizes 400 and 600 suit bigger ports and higher demand; size 200 suits compact drops. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.
There is no single rated flow to quote: AirTAC publishes G-series flow as curves. Tell us about your application and we will confirm the flow figures from the datasheet so you can verify the 3/8 in port is the right step before ordering.
This unit carries the embedded square gauge (code F) scaled in MPa, which sits in the regulator body. The alternative is an external round gauge (code C), orderable in MPa, psi or bar scales. Both show downstream pressure; the choice is mounting style and scale.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.