The AirTAC GFC Combination Unit GFC300C10F1K is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC300C10F1K is a two-unit F.R.L. set combining a GFR300 filter-regulator with a GL300 lubricator on a 3/8 in PT port, so filtration, regulation and lubrication come from a single order. This configuration uses the standard 40 um filter element, a differential-pressure drain, the embedded square gauge scaled in MPa, standard regulation with a 0.15-0.9 MPa (20-130 psi) adjust range, and the K option: a reverse/check valve fitted. Bowls on this size 300 set are polycarbonate.
This is a genuine AirTAC part. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The same set exists without the check valve, and the G series spans sizes 200, 300, 400 and 600 with manual or automatic drains, a 5 um element option, round external gauges, psi or bar scales and G (BSPP) or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm flow and datasheet details for your application.
| Model | Airtac GFC Combination Unit GFC300C10F1K |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · See datasheet · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-C1 |
| Build order | Filter regulator first, lubricator last |
Condition the air at a maintenance-bay drop feeding impact wrenches and ratchets, with the check valve helping isolate the tools from header backflow.
Supply the index and clamp cylinders of a multi-station rotary table with filtered, regulated and oiled air from one two-unit set.
Run high-cycle pick-and-place cylinders on a packaging cell, with the standard 40 um grade protecting the main directional valves.
Pick this code when you want the standard two-unit F.R.L. plus the check valve: it decodes as size 300, 3/8 in PT port, 40 um element, differential-pressure drain, embedded square MPa gauge and the K reverse/check valve. Otherwise the family lets you choose the 5 um element for finer filtration, manual or automatic drains (each with its own adjust range), a round external gauge in MPa, psi or bar, and G (BSPP) or NPT threads instead of PT. If your demand points to a bigger port, look at sizes 400 and 600. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.
Flow is published by AirTAC as curves rather than a single rated figure, so we do not state a number here. Provide your application details and we will confirm the flow data from the datasheet so you can check the 3/8 in port before ordering.
This GFC set is two pieces: a filter-regulator in one body plus a separate lubricator, so it filters, regulates and lubricates with fewer components. The GC combination is three separate units - filter, regulator and lubricator - which allows replacing or repositioning each one individually. Functionally both cover filter, regulate and lubricate.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.