verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac GFC Combination Unit GFC300C15C1K

The AirTAC GFC Combination Unit GFC300C15C1K is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$89.95 $95.87Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFC300-15 drain, gauge and thread option on one page All GFC300-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFC Combination Unit GFC300C15C1K

GFC300C15C1K is a two-piece AirTAC G-series air-treatment set: a filter regulator plus a lubricator, with a reverse (check) valve fitted as denoted by the K in the code. It removes water and particulate, regulates downstream pressure and adds oil mist, while the check valve holds the downstream circuit against backflow from the supply side. This configuration is sized 300 with a PT1/2 port (PT thread as standard), a differential-pressure drain, the standard 40 um element and a round gauge with MPa scale. Regulation covers 0.15-0.9 MPa (20-130 psi) with this drain type; the set carries compressed air at up to 1.0 MPa (145 psi) and works from -5 to 70 C (non-freezing). Both bowls on this 300 size are PC (polycarbonate).

This is a genuine AirTAC part sold by a distributor for the US market. The G-series spans 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, plus drain choices, 5 um (W) elements, gauge types and scales and G (BSPP) or NPT threads. AirTAC publishes flow as curves rather than a single rating, so share your application details and we will confirm sizing and datasheet figures on request.

Airtac GFC Combination Unit GFC300C15C1K Technical Specifications

ModelAirtac GFC Combination Unit GFC300C15C1K
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFC Combination Unit GFC300C15C1K

GFC300G-series two-unit set, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C1
Build orderFilter regulator first, lubricator last

Where the Airtac GFC Combination Unit GFC300C15C1K Is Used

factory

Bottling and filling lines

Conditions the air feeding star-wheel, capper and filler cylinders on a bottling line, where the check valve helps the circuit hold its set pressure through supply dips between fill cycles.

engineering

Robotic gripper cells

Supplies the gripper and clamp circuits on a robot cell with clean, regulated, lubricated air, while the reverse valve keeps the gripper circuit isolated from upstream pressure fluctuation.

valve

Actuated valve manifolds

Prepares the pilot and actuator supply for pneumatically actuated process valves, pairing the filter regulator with the lubricator so the actuator cylinders and pilot valves run on conditioned air.

Is the Airtac GFC Combination Unit GFC300C15C1K the Right Set?

The 300 size with a 1/2 inch PT port sits mid-range in the G-series; step to 200, 400 or 600 sizes if the flow curve for your circuit points elsewhere. The K option adds a reverse (check) valve, useful where a downstream circuit must hold pressure if the upstream supply drops; order the same code without K if you do not need it. This unit uses the differential-pressure drain, with automatic (A) and manual (M) drains available as catalogue options. The standard element is 40 um, and W gives 5 um. A round MPa-scale gauge is fitted; other gauge types and scales can be ordered. Thread is PT as standard, with G (BSPP) and NPT available to order, and a bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.

Airtac GFC Combination Unit GFC300C15C1K FAQ

AirTAC publishes G-series flow data as curves rather than a single rated figure, so there is no one rated flow number to quote. Tell us your working pressure and consumption and we will confirm sizing from the datasheet on request.

It indicates that a reverse (check) valve is fitted, which blocks backflow from the downstream side toward the supply. The same set without the K suffix is available if your circuit does not need this function.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFC Combination Unit GFC300C15C1K

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFC300C15C1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.