The AirTAC GFC Combination Unit GFC300C15F1K is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
GFC300C15F1K is an AirTAC G-series two-unit set combining a filter regulator and a lubricator in one pair, with a reverse (check) valve fitted so downstream air is held if the supply drops. The 300 size carries PT1/2 ports, the standard 40 um element removes water and particulate, the differential-pressure drain handles condensate, and the built-in square gauge reads outlet pressure in MPa. Regulator adjustment spans 0.15-0.9 MPa (20-130 psi) with this drain type.
This is a genuine AirTAC part in the 300 frame of the G series, which spans 200, 300, 400 and 600 sizes with ports from 1/8" to 1". Drain type, filter grade (40 or 5 um), gauge scale, check valve and G (BSPP) or NPT threads are catalogue options. Flow is published as curves rather than a single rating, so we confirm datasheet figures for your application on request.
| Model | Airtac GFC Combination Unit GFC300C15F1K |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · See datasheet · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-C1 |
| Build order | Filter regulator first, lubricator last |
Conditioning air to a pick-and-place gripper on an assembly cell: filtered, regulated and lubricated supply, with the check valve holding the circuit if shop air dips mid-cycle.
Supplying pneumatic actuators on a laboratory sample-handling manifold, where the 40 um element protects fine valves and the MPa gauge documents the operating setpoint.
Feeding air tools and clamps at a trailer assembly bay from a single PT1/2 drop, keeping particulate and water out of the tools while the lubricator mists their internals.
Choose the 200, 300, 400 or 600 frame for the port and flow your line needs; this 300 set is PT1/2, with G or NPT threads available to order. The K suffix adds a reverse (check) valve, useful where a drop in supply must not vent the regulated circuit. Drain options are the differential-pressure type fitted here, automatic or manual (manual shifts the regulator range to 0.05-0.9 MPa). Filter grade is the 40 um standard or the finer 5 um W element. The square MPa gauge is built in. Flow appears as curves, not a single rated figure, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.
AirTAC publishes flow for the G series as curves, not as one rated number, so we do not state a figure here. Share your working pressure and air consumption and we will confirm the datasheet curve and correct frame size on request.
K means a reverse (check) valve is fitted, so air is held downstream if the upstream supply falls. The same set is available without it; drop the K from the code when ordering if you do not need that function.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.