The AirTAC GFC Combination Unit GFC300C15MC1K is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The GFC two-unit set pairs a filter-regulator with a lubricator: the front unit removes water and particulate and regulates downstream pressure, while the lubricator feeds an oil mist into the line. The K in this code adds a reverse-flow check valve, so air is held downstream if supply pressure is lost. This 300-size configuration has PT1/2 (1/2 in) ports, a manual drain, the standard 40 um filter element and a round gauge scaled in MPa. Maximum working pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C, non-freezing.
This is a genuine AirTAC part from the G series, offered in 200, 300, 400 and 600 sizes with a choice of ports, PT/G/NPT threads, drain types, 40 um or 5 um filter grades and the check-valve option. Flow is published as curves rather than a single figure, so ask us to confirm sizing and datasheet details for your application before ordering.
| Model | Airtac GFC Combination Unit GFC300C15MC1K |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · See datasheet · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-C1 |
| Build order | Filter regulator first, lubricator last |
Keeps pneumatically actuated process valves in position during a supply interruption, with the check valve holding pressure on the downstream side.
Maintains clamped state on safeguarding cylinders at a stamping press if the plant air line drops, supporting a controlled hold rather than an instant release.
Conditions and regulates air to cleaning and blow-off nozzles, with the manual drain bled each shift in dusty filling-hall conditions.
Choose the K suffix when downstream equipment must stay pressurised if the supply drops - the check valve blocks back-flow toward the source. Otherwise the decode is standard for this size: 300 body, port code 15 = 1/2 in, PT thread as standard with G and NPT to order, manual drain (M) against differential-pressure or automatic (A), and 40 um filtration standard or 5 um with W. The gauge is the external round type, MPa scale, with square gauges and psi or bar scales as alternatives. Flow is published as curves, not a single rating, so ask us to confirm sizing against the application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.
AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote a number here. Share your line pressure, port size and flow requirement and we will confirm the sizing against the datasheet curves on request.
K specifies a reverse-flow (check) valve fitted in the unit: downstream pressure is retained if the upstream supply is lost. Without the K, the same set is ordered as GFC300C15MC1, so pick the suffix based on whether hold-on-failure matters in your circuit.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.