The AirTAC GFR Filter Regulator GFR300C08C1K is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C08C1K is an AirTAC GFR-series filter regulator: filtration and pressure regulation combined in one body, with a drain bowl but no lubricator. This 300-size unit takes a 1/4in PT port, carries the standard 40 um filter element and a differential-pressure drain, and is supplied with a round external gauge on the MPa scale. The trailing K means a reverse (check) valve is fitted, so downstream pressure is held if the upstream supply dips. It runs on compressed air at up to 1.0 MPa (145 psi) inlet, regulates from 0.15 to 0.9 MPa (20-130 psi) with this drain type, and works from -5 to 70 C. The bowl on a 300-size unit is PC (polycarbonate).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8in to 1in, plus options including 5 um filtration (W), automatic or manual drain, square or round gauges on MPa, psi or bar scales, G (BSPP) or NPT threads, and no-bracket variants. Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet for your application on request.
| Model | Airtac GFR Filter Regulator GFR300C08C1K |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C0 (two-unit set) |
Supplying clean, regulated air to pneumatic clamping fixtures on a CNC machining cell, where the fitted check valve holds clamp pressure if the main supply dips.
Point-of-use air prep for cylinder-driven carton sealing and labelling heads on a packaging line, fed at a 1/4in takeoff from the main header.
Feeding regulated, particulate-filtered air to spray guns in a paint finishing booth, with the bowl catching condensate before it reaches the nozzle.
The decodable choices here are: size and port (300 with a 1/4in PT port sits mid-range; step up to 400/600 for larger ports and more flow), filter grade (40 um standard vs the 5 um W option), drain type (differential-pressure as coded here, automatic A, or manual M, which also widens the regulating range down to 0.05 MPa / 7 psi), gauge style and scale (round MPa as coded, or square, on MPa/psi/bar), thread (PT is standard; G and NPT are catalogue options to order) and the bracket. The K in this code means the reverse (check) valve is already fitted. Because AirTAC publishes flow only as curves, not a single rating, send us your pressure and demand and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as performance curves, not as a single rated number, so we do not quote a flow figure on the page. Tell us your inlet pressure, downstream demand and allowed pressure drop, and we will confirm the correct sizing from the datasheet on request before you order.
It means a reverse (check) valve is fitted. If upstream pressure falls, the valve keeps the regulated pressure downstream instead of letting it bleed back, which is useful on clamp and hold circuits. The equivalent code without K is supplied without the check valve.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.