verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

Airtac GFR Filter Regulator GFR300C08MC1WK

The AirTAC GFR Filter Regulator GFR300C08MC1WK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$58.42 $63.55Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR300-08 drain, gauge and thread option on one page All GFR300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFR Filter Regulator GFR300C08MC1WK

GFR300C08MC1WK is an AirTAC G-series filter regulator: filtration and pressure regulation in one body, for compressed air only. This 300-size unit carries a PT1/4 port, a manual-drain PC (polycarbonate) bowl, the finer 5 um filter element (W option), an external round pressure gauge on the MPa scale, and the K-option reverse/check valve fitted. Regulation range with manual drain is 0.05-0.9 MPa (7-130 psi); max working pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR series runs from size 200 to 600 with ports from 1/8 to 1 inch and G (BSPP) or NPT thread options; automatic and differential-pressure drains, the standard 40 um element and other gauge choices sit on neighbouring codes. AirTAC publishes flow as curves rather than a single rating, so we confirm sizing and datasheet figures on request.

Airtac GFR Filter Regulator GFR300C08MC1WK Technical Specifications

ModelAirtac GFR Filter Regulator GFR300C08MC1WK
SeriesGFR300 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFR Filter Regulator GFR300C08MC1WK

GFR300G-series filter regulator, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · See datasheet · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-C0 (two-unit set)

Where the Airtac GFR Filter Regulator GFR300C08MC1WK Is Used

settings_input_component

Robotic gripper cell air prep

Conditioning and regulating supply to gripper valves on a robot cell, with the check valve fitted in the circuit as specified and the manual drain bled at shift start.

build

Leak-test rig air supply

Feeding a bench leak-test rig where the 5 um element is specified to keep fine particulate away from the test instrumentation and the regulator sets the test pressure.

science

Lab pneumatic bench services

Regulating bench air to lab apparatus and pneumatic jigs, with the external MPa gauge giving a clear set point and the manual drain emptied as part of the lab routine.

Is the Airtac GFR Filter Regulator GFR300C08MC1WK the Right Unit?

Step up or down a size (200/300/400/600) to match the pipe port and duty of your line; 300 corresponds to the 1/4 inch PT port on this code. Manual drain suits points where an operator bleeds the bowl on a schedule; automatic or differential-pressure drains suit unattended installs. The W selects the 5 um element instead of the standard 40 um grade, and the K suffix adds the reverse/check valve - order the code without K if you do not need it. The gauge is the external round type on MPa; square-face and psi/bar scales exist on other codes. PT is the standard thread; G (BSPP) and NPT are catalogue options to order. Flow is published as curves, not a single rating - ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

Airtac GFR Filter Regulator GFR300C08MC1WK FAQ

AirTAC publishes G-series flow as curves, not a single rated figure, so we will not quote a made-up number. Give us your inlet pressure and required demand and we will confirm the fit against the datasheet curves on request before ordering.

K specifies that the reverse/check valve is fitted in this unit; the same filter regulator without the K suffix omits it. If your circuit already handles back-flow elsewhere, order the non-K variant of this 300-size, 1/4 inch PT, manual-drain code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFR Filter Regulator GFR300C08MC1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR300C08MC1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.