The AirTAC GFR Filter Regulator GFR300C08MJNWK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR300C08MJNWK is an AirTAC GFR-series filter regulator: filtration plus pressure regulation in one body with a drain bowl, and no lubricator. This configuration is sized 300 with a PT1/4 (1/4 inch) port, carries the fine 5 um filter element (code W) and has a manual drain. The code's J and N mean it is supplied without a mounting bracket or pressure gauge, and the trailing K means a reverse (check) valve is fitted.
It is a genuine AirTAC part for compressed air only, rated to 1.0 MPa (145 psi) maximum inlet pressure, -5 to 70 C (non-freezing), with a polycarbonate bowl at size 300. With manual drain, the outlet pressure setting range is 0.05-0.9 MPa (7-130 psi). The GFR family spans sizes 200/300/400/600 with 1/8 to 1 inch ports; flow is published as curves rather than a single rated figure, so we confirm datasheet figures on request.
| Model | Airtac GFR Filter Regulator GFR300C08MJNWK |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C0 (two-unit set) |
Sets the test pressure feeding a bench leak-testing fixture; the code K means a reverse (check) valve is fitted in the body for this configuration.
Feeds pneumatic holding fixtures in a laboratory, where the 5 um element is specified and the technician sets pressure at the regulator knob.
Placed upstream of pilot valves and small-orifice components on an automation panel, delivering regulated air through the fine element.
Choose the 300 size with PT1/4 port for mid-range duties, or step to 200/400/600 as your required flow dictates - we will confirm sizing against the published curves before you order. The W selects the 5 um element over the standard 40 um, and manual drain (code M) gives the full 0.05-0.9 MPa (7-130 psi) setting range; automatic and differential-pressure drains are the family alternatives. This unit is supplied without gauge or bracket (both are options), PT is the standard thread with G and NPT orderable, and the K specifies the fitted reverse (check) valve - delete the K if you do not need it.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
There is no single rated flow figure for the GFR300 - AirTAC publishes flow as curves. We do not estimate a number here; ask us and we will confirm the sizing against the datasheet for your pressure and consumption.
K indicates that a reverse (check) valve is fitted in this unit. The rest of the code decodes as 300 size, PT1/4 port, manual drain, 5 um filter element, no gauge and no bracket; the same unit without the valve drops the K.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.