verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

Airtac GFR Filter Regulator GFR300C10ANWK

The AirTAC GFR Filter Regulator GFR300C10ANWK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$63.16 $68.41Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR300-10 drain, gauge and thread option on one page All GFR300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFR Filter Regulator GFR300C10ANWK

GFR300C10ANWK is a genuine AirTAC G-series filter regulator in one body: it cleans the air to 5 um and regulates downstream pressure. This 300-size unit has a PT 3/8 in port, the fine W-grade 5 um element, an automatic drain that empties the PC (polycarbonate) bowl without attention, and a fitted reverse (check) valve that resists backflow and helps hold the set pressure if the supply drops. Outlet pressure adjusts from 0.15 to 0.9 MPa (20 to 130 psi) with a maximum inlet of 1.0 MPa (145 psi). No gauge is fitted; a mounting bracket is included. Operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part distributed for the US market. The G-series filter regulators come in 200, 300, 400 and 600 sizes with 1/8 in to 1 in ports, PT, G (BSPP) or NPT thread options, differential-pressure, automatic or manual drains, 40 um or 5 um elements, and optional check valve and gauges. AirTAC publishes flow as curves, not a single rating, so we confirm datasheet figures for your application on request.

Airtac GFR Filter Regulator GFR300C10ANWK Technical Specifications

ModelAirtac GFR Filter Regulator GFR300C10ANWK
SeriesGFR300 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFR Filter Regulator GFR300C10ANWK

GFR300G-series filter regulator, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · See datasheet · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-C1 (two-unit set)

Where the Airtac GFR Filter Regulator GFR300C10ANWK Is Used

build

Pneumatic clamping fixture on a machining centre

Feed a clamping fixture where losing pressure mid-cut is unacceptable: the check valve holds the clamp circuit if upstream supply dips, and the 5 um element protects the pilot valves.

valve

Pilot valve supply on a bottling line

Condition the air feeding pilot-operated valves on a filling and capping line; the fine element keeps particulate out of the valve seats and the automatic drain handles condensate.

settings_input_component

Sorter control valves in a distribution centre

Regulate and clean the supply to a sorter's valve bank: 5 um filtration guards the solenoid valves while the check valve backs the circuit through compressor cycling.

Is the Airtac GFR Filter Regulator GFR300C10ANWK the Right Unit?

Use the 300 body with its 3/8 in PT port for circuits whose demand sits above what a 200 unit carries comfortably, and step to 400 or 600 for large actuators; we verify the exact flow curve on request. This code combines the choices that matter on critical circuits: the 5 um W element for cleaner air, the automatic drain for unattended mounting, and the K check valve where a supply dip must not dump your regulated circuit. If you do not need backflow protection, the non-K variant is the same unit without it. Thread is PT as the standard, with G and NPT available to order; a bracket is included and a gauge can be added for a visible setpoint. Ask us to confirm sizing from the datasheet curves before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

Airtac GFR Filter Regulator GFR300C10ANWK FAQ

No single figure exists to quote responsibly: AirTAC publishes G-series performance as flow curves over a pressure range. Send us your operating pressure and demand and we will confirm the right size from the datasheet on request.

N means no gauge is fitted on this code. The G series is offered with an embedded square gauge as standard equipment, and an external round gauge with MPa, psi or bar scale is a catalogue option, so a gauged variant can be specified instead. Ask us to identify the matching gauged code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFR Filter Regulator GFR300C10ANWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR300C10ANWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.