verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

Airtac GFR Filter Regulator GFR300C10N

The AirTAC GFR Filter Regulator GFR300C10N is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$41.37 $46.08Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR300-10 drain, gauge and thread option on one page All GFR300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFR Filter Regulator GFR300C10N

The AirTAC GFR family filters and regulates compressed air in a single body: the bowl collects water and particles for the drain to remove, while the adjusting knob sets the downstream pressure. This model is the 300 size with a PT3/8 port, the standard 40 um element and the default differential-pressure drain, and no pressure gauge is fitted. Maximum inlet pressure is 1.0 MPa (145 psi); with the differential-pressure drain the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi).

This is a genuine AirTAC part from the G series, spanning sizes 200 to 600 (1/8 in. to 1 in. ports) with 40 um or 5 um elements, differential-pressure, automatic or manual drains, and gauge or no-gauge variants. The 300 size carries a polycarbonate bowl and works on non-freezing compressed air from -5 to 70 C. Flow appears in the catalogue as curves rather than a single rated figure, so we confirm datasheet and flow figures on request.

Airtac GFR Filter Regulator GFR300C10N Technical Specifications

ModelAirtac GFR Filter Regulator GFR300C10N
SeriesGFR300 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFR Filter Regulator GFR300C10N

GFR300G-series filter regulator, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · See datasheet · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-C1 (two-unit set)

Where the Airtac GFR Filter Regulator GFR300C10N Is Used

conveyor_belt

Stopper and gate cylinders on conveyors

Regulating the supply to stopper, lift and divert cylinders along a roller conveyor line, with the differential-pressure drain clearing bowl condensate as the line cycles.

valve

Actuated ball-valve panels

Providing clean, regulated air to solenoid valves and quarter-turn actuators on a water or process skid, ahead of the valve manifold.

factory

Assembly cell supply header

Serving as the point-of-use filter-regulator on the air drop feeding a small assembly cell's cylinders and air-operated fixtures.

Is the Airtac GFR Filter Regulator GFR300C10N the Right Unit?

Choose the frame by port and air demand: 200 = 1/4 in., 300 = 3/8 in., 400 = 1/2 in. and 600 upward, so the 300 sits mid-range. The blank drain code here is the differential-pressure type, which ejects condensate using the pressure differential across the unit; automatic (A) and manual (M) drain variants can be ordered if the bowl is mounted where a hand cannot reach. The standard element grade is 40 um, with 5 um (W) for finer duty, and no gauge is fitted in this code - gauge variants exist in the series. Thread is PT as standard with G (BSPP) and NPT as options, and the bracket is included unless J is specified.

Flow is published as curves, not a single rating, so ask us to confirm sizing against your line conditions before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

Airtac GFR Filter Regulator GFR300C10N FAQ

AirTAC publishes G-series flow as curves, not as a single rated figure, so we do not quote a l/min or SCFM number here. Send us your inlet pressure and air demand and we will confirm the flow and sizing from the datasheet on request.

With no drain letter in the code, the unit carries the differential-pressure drain, which expels condensate from the bowl using the pressure differential across the regulator. Automatic (A) and manual (M) drain variants, 5 um elements and G or NPT threads can be ordered in the same series.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFR Filter Regulator GFR300C10N

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR300C10N and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.