The AirTAC GFR Filter Regulator GFR300C15AF1W is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR series combines compressed-air filtration and pressure regulation in one body. This GFR300C15AF1W is a size 300 unit with a PT1/2 port, the 5 um fine-filtration element (W) in place of the standard 40 um, an automatic drain that purges condensate without operator attention, and the embedded square pressure gauge with MPa scale. Maximum working pressure is 1.0 MPa (145 psi); regulation range for the automatic-drain version is 0.15-0.9 MPa (20-130 psi); temperature range is -5 to 70 C (non-freezing). The bowl is polycarbonate, standard on the 300 size.
This is a genuine AirTAC part. The G series is offered in sizes 200, 300, 400 and 600 with 1/8 in to 1 in ports, drain choices (differential-pressure, automatic, manual), 40 um standard or 5 um fine elements, gauge and scale options, PT, G or NPT threads, and check-valve or low-pressure variants. Flow is published as curves rather than a single rated figure, so we confirm flow and datasheet figures on request.
| Model | Airtac GFR Filter Regulator GFR300C15AF1W |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Feeding cleaned, regulated air to pneumatic test rigs and instrument panels in a lab, where the 5 um element protects sensitive pilot valves and gauges from fine particulate.
Conditioning supply air ahead of spray and coating equipment, where fine filtration supports consistent atomiser valve operation and the auto drain keeps moisture out during runs.
Supplying stable low-flow regulated air to positioner and I/P transducer loops on process valves, with the square MPa gauge giving a clear local pressure reading.
Size 300 with a PT1/2 port is the mid-range frame; step up to 400 or 600 for larger ports and more flow, or down to 200 for compact lines. The W code selects the 5 um element for finer filtration than the standard 40 um - the right choice where sensitive valves or instruments sit downstream. Automatic drain (A) suits unattended operation. The embedded square gauge reads in MPa here; round gauges and psi or bar scales are orderable. PT is the standard thread, with G (BSPP) and NPT as catalogue options; a bracket can be omitted with the J variant. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR300 as curves rather than a single rated figure, so no single number is quoted here. Tell us your downstream demand and working pressure and we will confirm the correct sizing and provide the datasheet figures on request.
The standard element is 40 um, adequate for general cylinders and valves. The W code fits a 5 um element for finer filtration - better protection for pilot valves, instruments and process control devices, at the cost of more frequent element attention. Both are order-time choices on the same GFR300 body.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.