The AirTAC GFR Filter Regulator GFR300C15AJF1WK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C15AJF1WK is an AirTAC GFR300 filter-regulator: water and particulate filtration plus pressure regulation combined in a single body, with no lubrication stage. This 300-size unit takes 1/2 in PT ports (PT is the standard thread for this code), drains its polycarbonate bowl automatically, carries the finer 5 um filter element, and has an embedded square pressure gauge scaled in MPa. The K option adds a reverse (check) valve that holds downstream pressure if the upstream supply fails. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) with the automatic drain, and the working temperature range is -5 to 70 C.
This is a genuine AirTAC part from the G series, which spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in. Across the range you can specify differential-pressure, automatic or manual drains, 40 um or 5 um elements, embedded square or external round gauges in MPa, psi or bar, G (BSPP) or NPT threads, a mounting bracket and a reverse valve. Rated flow is published only as characteristic curves, not as a single figure, so send us your operating conditions and we will confirm sizing and provide the datasheet on request.
| Model | Airtac GFR Filter Regulator GFR300C15AJF1WK |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Air prep for a clamping or riveting fixture at a machining cell: the MPa gauge lets the setter verify clamping pressure at the point of use, and the check valve holds the clamp if the main supply is shut down.
Conditioning air for case packers and wrapping machines on a packaging line: the 5 um element guards directional control valves and cylinders from particulate, and the automatic drain clears condensate through continuous shifts.
Feeding air to actuated ball and butterfly valves on a process skid: filtered, regulated air keeps the actuators inside their rated pressure, and the automatic drain copes with humid compressor air.
Size the unit on the air your downstream equipment actually consumes: 300 with 1/2 in PT ports is the mid range, stepping up to 400 or 600 adds port and flow capacity, while 200 or 300 serve lighter circuits. The automatic drain suits unattended, multi-shift installations; a manual drain variant needs operator attention but allows regulation down to 0.05 MPa (7 psi). The 5 um element (W) here protects finer valves and tools, against the 40 um standard element. The square MPa gauge is fitted; round external gauges in other scales can be ordered. The check valve blocks backflow from the downstream side. PT is the standard thread and G (BSPP) or NPT are order options; a bracket is optional and omitted in this code. Because AirTAC publishes flow as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR300 as characteristic curves rather than one rated figure, so we do not quote a single number. Share your upstream pressure and the air consumption of the equipment you are supplying, and we will confirm sizing from the datasheet on request.
The F1 option fits the embedded square pressure gauge with MPa scale so pressure can be read and set locally, and the K option fits a reverse (check) valve that holds downstream pressure if supply is interrupted. Both are order choices across the GFR300 range, alongside drain type, element grade and thread.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.