AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

Airtac GFR Filter Regulator GFR400C10AJC1K

The AirTAC GFR Filter Regulator GFR400C10AJC1K is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$91.56 $97.52Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR400-10 drain, gauge and thread option on one page All GFR400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFR Filter Regulator GFR400C10AJC1K

GFR400C10AJC1K is an AirTAC G-series filter regulator with a reverse/check valve (K) fitted, so downstream air cannot flow back through the unit toward the supply side. Beyond that option it is the same configuration as GFR400C10AJC1: 400-size filter-plus-regulator in one body, PT3/8 port, automatic drain, 40 um standard filter element, external round gauge scaled in MPa, and no mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi), the adjustment range with automatic drain is 0.15-0.9 MPa (20-130 psi), the working temperature is -5 to 70 C, and the 400-size bowl is PC (polycarbonate).

This is a genuine AirTAC part. Across the G series the filter regulator comes in 200 to 600 sizes, ports from 1/8 to 1 inch, three drain types, 40 um or 5 um elements, square or round gauges in MPa, psi or bar, G (BSPP) or NPT threads, and the K check-valve option. Flow is published as curves rather than one rated figure, so we confirm flow and datasheet figures on request.

Airtac GFR Filter Regulator GFR400C10AJC1K Technical Specifications

ModelAirtac GFR Filter Regulator GFR400C10AJC1K
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFR Filter Regulator GFR400C10AJC1K

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the Airtac GFR Filter Regulator GFR400C10AJC1K Is Used

build

Pneumatic press workholding

Supplying the clamping circuit of a pneumatic workholding press, where the check valve keeps downstream air from bleeding back toward the supply side if upstream pressure drops.

factory

Palletizer gripper supply

Conditioned, regulated air for the gripper and clamping cylinders on a robotic palletizer cell, with the 3/8 inch port feeding the valve manifold on the arm base.

settings_input_component

Multi-station assembly machine

Air preparation for the cylinder bank of a rotary-index assembly machine, where the check valve isolates the stations from supply-side loss so a drop upstream does not release the loaded parts.

Is the Airtac GFR Filter Regulator GFR400C10AJC1K the Right Unit?

Pick this code over GFR400C10AJC1 when the circuit behind the unit must be isolated from supply-side air loss - the K suffix adds the reverse/check valve and changes nothing else in the decode. Size from the port and flow: 400 size with a 3/8 inch PT port is the step above the 300 series; AirTAC publishes flow as curves rather than a single rating, so ask us to confirm sizing against the curves for your demand. The automatic drain suits unattended duty and gives a 0.15-0.9 MPa (20-130 psi) adjustment range; manual-drain versions reach 0.05-0.9 MPa (7-130 psi). The 40 um element is standard, with 5 um (W) available. The external round gauge reads in MPa; square-gauge, psi and bar variants exist. Thread is PT as standard with G (BSPP) and NPT as catalogue options, and J means no bracket is fitted.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

Airtac GFR Filter Regulator GFR400C10AJC1K FAQ

AirTAC publishes flow for the G series as curves, not as a single rated number, so there is no figure to quote here. Give us your line pressure and required flow and we will confirm against the datasheet curves that the 400 size with the 3/8 inch port is right before you order.

Only one thing: a reverse/check valve is fitted, so downstream air cannot flow back through the unit toward the supply. Everything else in the decode is identical - 400 size, PT3/8 port, automatic drain, 40 um element, external round MPa gauge, no bracket, PC bowl.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFR Filter Regulator GFR400C10AJC1K

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10AJC1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.