The AirTAC GFR Filter Regulator GFR400C10C1K is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR series combines a water-and-particulate filter and a pressure regulator in one body. This GFR400C10C1K is a 400-size unit with a PT3/8 port, a differential-pressure drain that bleeds condensate as airflow passes through, a 40 um standard filter element, a round pressure gauge reading in MPa and a fitted reverse (check) valve that helps hold downstream pressure if the upstream supply dips. It is a filter regulator only - there is no lubricator in this body. It runs on compressed air at up to 1.0 MPa (145 psi) inlet, adjusts outlet pressure from 0.15 to 0.9 MPa (20-130 psi), and works from -5 to 70 C (non-freezing). The 400 size uses a polycarbonate bowl.
This is a genuine AirTAC part. The G series is offered in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, and this configuration can be ordered instead with a G (BSPP) or NPT thread, an automatic or manual drain, a 5 um element, an embedded square gauge, or without the check valve. AirTAC publishes flow as characteristic curves rather than a single rating, so ask us to confirm sizing and request the datasheet for your application.
| Model | Airtac GFR Filter Regulator GFR400C10C1K |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Supplying clamping cylinders on a welding or assembly fixture, where the regulator holds the clamp pressure and the fitted check valve helps keep the circuit from relaxing if the plant supply drops momentarily.
Conditioning the supply to a chuck, vise or collet-actuation circuit on a CNC machine tool, keeping moisture and swarf-carrying air out of the actuator while holding a stable set pressure.
Regulating the air that strokes pneumatically actuated process valves on a water-treatment or chemical dosing skid, with one 3/8 inch conditioned branch per valve group.
The 400 size with its 3/8 inch port sits in the middle of the G range; step down to 300 or up to 600 when your line volume calls for a different port, and match the step against the flow curves before ordering. The differential-pressure drain suits continuously flowing lines; the A-coded automatic drain covers intermittent duty and the M-coded manual drain allows hand bleeding plus a wider 0.05-0.9 MPa (7-130 psi) regulating range. The K suffix here means a reverse (check) valve is already fitted; order the non-K code if you do not want it. The 40 um element is standard, with 5 um available under W. PT is the standard thread with G (BSPP) and NPT as catalogue options, a bracket is included, and the MPa round gauge can be ordered as an embedded square gauge instead. AirTAC publishes flow as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as characteristic curves rather than a single rated number, so we do not quote one figure as a rating. Send us your supply pressure, set pressure and air consumption and we will confirm sizing against the curves and provide the datasheet on request.
K means a reverse (check) valve is fitted in this unit: air passes normally from inlet to outlet, but reverse flow from the downstream side is blocked. That helps hold pressure on the equipment side during upstream dips; if you do not want the check function, order the non-K code GFR400C10C1.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.