The AirTAC GFR Filter Regulator GFR400C10F1 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR400 series is a filter regulator: filtration and pressure regulation built into one body, with a drain bowl and no lubricator. This GFR400C10F1 is the 400 size on a PT3/8 port (standard PT thread), configured with the differential-pressure drain, a 40 um element and the embedded square gauge on a MPa scale; the C in the code also specifies the round external gauge. Maximum working pressure is 1.0 MPa (145 psi), the regulation span is 0.15-0.9 MPa (20-130 psi) with the differential-pressure drain, and the polycarbonate (PC) bowl unit runs on compressed air from -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The G series spans 200, 300, 400 and 600 frames with ports from 1/8 to 1 in, and within this family you can order automatic or manual drains, a 5 um element (W), a reverse/check valve (K), other gauge scales, no-gauge (N) and no-bracket (J) versions, and G (BSPP) or NPT threads instead of PT. AirTAC publishes flow as performance curves rather than a single rated figure, so we confirm datasheet and flow values on request.
| Model | Airtac GFR Filter Regulator GFR400C10F1 |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Filtering and regulating the 3/8 in air drop that feeds gripper and clamp cylinders on a case-packing machine, so carton-pick actuators work from clean, steady pressure.
Conditioning the compressed-air branch that drives filler valves and stopper presses on a rotary bottling line, with the MPa gauge giving operators a clear setpoint to work to.
Regulating the supply to pneumatic clamps on a machining fixture, setting a repeatable clamp pressure at the fixture rather than back at the compressor.
Size and port step up together: the 200/300/400/600 frames carry progressively larger ports and flow, and this 400 unit takes a 3/8 in PT connection. The drain choice is real: the coded differential-pressure drain quotes a 0.15-0.9 MPa (20-130 psi) regulation span, while manual-drain versions widen it to 0.05-0.9 MPa (7-130 psi), and an automatic drain is also a catalogue option. Element grade is 40 um as coded or 5 um with W, and gauge scales come in MPa, psi or bar. Thread is PT as standard, with G (BSPP) and NPT as catalogue options, and the bracket is included (J deletes it). Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as performance curves, not as a single rated figure, so we do not quote a number here. Tell us your flow and pressure conditions and we will confirm the datasheet figures and the correct size on request before you order.
It is the coded drain: the bowl vents collected condensate according to the pressure differential, with no operator action needed. Automatic and manual drains are catalogue alternatives - note the regulation span is 0.15-0.9 MPa (20-130 psi) with this drain, while manual-drain versions are quoted from 0.05 MPa.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.