The AirTAC GFR Filter Regulator GFR400C10JC1K is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR400C10JC1K is an AirTAC G-series filter regulator: filtration and pressure regulation combined in a single body, with a drain bowl but no lubricator. This size 400 configuration uses a 3/8 in PT port, the standard 40 um filter element and a differential-pressure drain, and the K code adds a reverse (check) valve so air cannot flow backwards through the unit. The C1 code specifies an external round pressure gauge with MPa scale, and J means no mounting bracket is included. With this drain type the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi) at a maximum working pressure of 1.0 MPa (145 psi). The medium is compressed air only, service temperature is -5 to 70 C (non-freezing), and the 400-size bowl is PC (polycarbonate).
This is a genuine AirTAC part. The same GFR family spans sizes 200 to 600 with ports from 1/8 to 1 in, and lets you specify drain type (differential-pressure, automatic or manual), element grade (40 um standard, 5 um optional), gauge style and scale, the check valve option, thread (PT standard; G and NPT as ordered variants) and bracket. Flow for this series is published as curves rather than a single rating, so ask us to confirm the datasheet figures against your application.
| Model | Airtac GFR Filter Regulator GFR400C10JC1K |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Dropping pressure on a branch feeding a secondary circuit in the compressor room, with the fitted check valve blocking backflow toward the supply when the upstream header is vented.
Feeding a dedicated clamp circuit on a machining fixture at its own set pressure, with the check valve preventing reverse flow through the unit if the downstream side remains pressurized.
Supplying pneumatically actuated diverter and stopper gates along a conveyor line, keeping supply dips from back-feeding the regulator during venting or shutdown.
Choose this K version over the plain GFR400C10JC1 when the downstream side can stay pressurized or the upstream line can be vented, and you want backflow through the unit blocked. Everything else is the same ordering decision set: size step 200/300/400/600 for port and duty (here 400 on a 3/8 in PT port), drain type (this model is differential-pressure; automatic and manual exist), element grade 40 um standard or 5 um with W, and gauge style and scale (here external round, MPa; square embedded, psi and bar scales are options). Thread is PT as standard, with G (BSPP) and NPT as ordered variants, and J omits the bracket. Flow is published as curves, not a single rating - ask us to confirm sizing against the datasheet before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
For the GFR400 size, flow is published as performance curves rather than a single rated figure, so we do not quote one number. Share your inlet pressure, set pressure and flow requirement and we will confirm the sizing against the datasheet on request.
It fits a reverse (check) valve in the unit, so air cannot flow backwards through the filter regulator if the downstream side stays pressurized or the upstream line is vented. Everything else in the code - the 3/8 in PT port, 40 um element, MPa round gauge, no bracket - is identical to the plain version.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.