The AirTAC GFR Filter Regulator GFR400C10JNK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR series filters and regulates compressed air in one body: a 40 um element removes water and particulate, and the regulator holds a steady downstream pressure adjustable between 0.15 and 0.9 MPa (20-130 psi) with the differential-pressure drain this code specifies. The K in GFR400C10JNK adds a reverse (check) valve, so air held downstream cannot flow back through the unit when the upstream supply is vented or the compressor unloads. This size 400 unit has a 3/8 in PT port, no gauge (N) and no mounting bracket (J); the polycarbonate bowl suits non-freezing air from -5 to 70 C at up to 1.0 MPa (145 psi) inlet.
It is a genuine AirTAC part. The G series covers sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, plus drain, filter-grade, gauge, bracket and thread options in G (BSPP) or NPT as well as PT. Flow is published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application.
| Model | Airtac GFR Filter Regulator GFR400C10JNK |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
On a bench pneumatic press, the built-in check valve keeps the regulated pressure trapped downstream when the compressor unloads or the upstream valve vents, so the workpiece stays clamped between strokes.
Filtering and regulating the air feeding bagger and cartoner actuators on a snack-food packaging line, with the check valve holding actuator pressure while the plant air header cycles.
Regulating air to diaphragm-actuated control valves on a water-treatment skid; the reverse valve stops backflow through the unit when the air header is isolated for service.
Pick this JNK build over the plain GFR400C10JN whenever downstream pressure must be trapped - clamps, presses or cylinders that must not relax when the supply side drops. Filtration and regulation are unchanged: 40 um standard element, 0.15-0.9 MPa regulation with the differential-pressure drain (0.05-0.9 MPa if you choose the manual-drain code instead), and a 3/8 in PT port that steps to 1/2 in on the 15 code. Gauge (N means none here), bracket, 5 um element and G or NPT thread variants can all be ordered.
AirTAC publishes flow as curves, not one rated number, so share your pressure and demand points and we will confirm sizing from the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
We do not quote a single rated flow because AirTAC publishes G-series performance as curves, not one number. Tell us your supply pressure, set pressure and air demand, and we will confirm the sizing data from the datasheet on request.
K fits a reverse (check) valve, so downstream air cannot flow back through the unit - useful for holding regulated pressure on cylinders and tools while the supply side is vented or the compressor unloads. Everything else decodes the same as the plain GFR400C10JN: 3/8 in PT port, 40 um element, differential drain, no gauge and no bracket.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.