verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

Airtac GFR Filter Regulator GFR400C10JNW

The AirTAC GFR Filter Regulator GFR400C10JNW is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$64.07 $69.34Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR400-10 drain, gauge and thread option on one page All GFR400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFR Filter Regulator GFR400C10JNW

The AirTAC GFR series filters and regulates compressed air in one body. This JNW build carries the W filter grade - a 5 um element instead of the standard 40 um - so finer particulate is taken out before the air reaches sensitive downstream equipment, while the regulator holds a set pressure adjustable between 0.15 and 0.9 MPa (20-130 psi) with the differential-pressure drain this code specifies. It is the size 400 unit with a 3/8 in PT port, no gauge (N) and no mounting bracket (J); the polycarbonate bowl suits non-freezing air from -5 to 70 C at up to 1.0 MPa (145 psi) inlet.

It is a genuine AirTAC part. The G series spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and the same body is offered with 40 um or 5 um filtration, automatic or manual drains, gauges, brackets, a reverse check valve and G or NPT threads. Flow is published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application.

Airtac GFR Filter Regulator GFR400C10JNW Technical Specifications

ModelAirtac GFR Filter Regulator GFR400C10JNW
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFR Filter Regulator GFR400C10JNW

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the Airtac GFR Filter Regulator GFR400C10JNW Is Used

science

QC lab analyzer cabinets

Supplying clean, regulated air to moisture analyzers and sample-handling hardware in a quality-control lab, where the 5 um element is specified over the standard 40 um grade for finer particulate control.

precision_manufacturing

Machining-center pallet clamps

Regulating clamp pressure on a CNC machining center's pallet-changing fixtures, with the 5 um element protecting pilot valves and small-bore clamp circuits fed from the 3/8 in machine air drop.

settings_input_component

I/P transducer and pilot lines on a packaging skid

Feeding I/P transducers and pilot-operated valves on a packaging skid, where fine particulate in the supply would upset the small signal-side orifices these components rely on.

Is the Airtac GFR Filter Regulator GFR400C10JNW the Right Unit?

Choose 5 um (W) over the standard 40 um when the equipment fed downstream is sensitive to fine particles - instruments, pilot valves, transducers, air bearings or tight-tolerance tools. Regulation stays the same: 0.15-0.9 MPa with this differential-pressure drain, or 0.05-0.9 MPa if you select the manual-drain code. The 3/8 in PT port (10) is fixed for this code; 1/2 in on the 15 code is the next step within size 400, and dropping to size 300 suits smaller lines. Gauge (none on this JN build), bracket, check valve (K) and G or NPT thread variants can all be ordered.

Flow is published as curves, not a single rating, so send us your pressure and demand points and we will confirm sizing from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

Airtac GFR Filter Regulator GFR400C10JNW FAQ

AirTAC publishes G-series flow as performance curves rather than a single rated figure, so we do not state one number. Give us your upstream pressure, set pressure and air consumption, and we will confirm the flow data from the datasheet on request.

The W in GFR400C10JNW swaps the standard 40 um element for a 5 um grade, which suits downstream equipment that is sensitive to fine particles such as instruments, transducers and pilot valves. Regulation range, drain, port and bowl details are otherwise identical to the plain GFR400C10JN.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFR Filter Regulator GFR400C10JNW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10JNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.