AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

Airtac GFR Filter Regulator GFR400C10MJF1WK

The AirTAC GFR Filter Regulator GFR400C10MJF1WK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$81.12 $86.82Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR400-10 drain, gauge and thread option on one page All GFR400-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFR Filter Regulator GFR400C10MJF1WK

GFR400C10MJF1WK is an AirTAC G-series filter regulator: one body that removes water and particulate from compressed air and holds downstream pressure at your setpoint. This 400-size unit is drilled for PT 3/8 in ports, carries the finer 5 um filter element (W code), and has a manual drain on the PC (polycarbonate) bowl. It is supplied without a mounting bracket (J code), the embedded square gauge reads in MPa, and the K code adds a reverse (check) valve. With the manual drain, the regulator adjustment range is 0.05-0.9 MPa (7-130 psi); maximum working pressure is 1.0 MPa (145 psi).

This is a genuine AirTAC part from the 200/300/400/600 G-series range. Elsewhere in the series you can order G (BSPP) or NPT threads and automatic or differential-pressure drains. The temperature range is -5 to 70 C, non-freezing. Flow for this series is published as curves rather than a single rating, so ask us to confirm the datasheet figure for your application.

Airtac GFR Filter Regulator GFR400C10MJF1WK Technical Specifications

ModelAirtac GFR Filter Regulator GFR400C10MJF1WK
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFR Filter Regulator GFR400C10MJF1WK

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the Airtac GFR Filter Regulator GFR400C10MJF1WK Is Used

science

Lab actuator supply

Conditions air for the small actuators and sample-handling cylinders on a laboratory automation bench, with the 5 um element protecting compact valves from finer debris.

valve

Paint booth atomizing air

Feeds filtered, regulated atomizing air to spray nozzles in a finishing booth, with the check valve isolating the nozzle circuit from supply-side fluctuations.

precision_manufacturing

Pick-and-place grippers

Prepares the supply for vacuum ejectors and gripper cylinders on a pick-and-place cell, holding a stable setpoint through repeated fast cycles.

Is the Airtac GFR Filter Regulator GFR400C10MJF1WK the Right Unit?

Size 400 with a 3/8 in port sits above the 300/1/4 in step and below 600/1/2 in - choose the step from the flow your line needs, not the pipe size alone. The W code gives the 5 um element for finer filtration, and the K code fits a reverse (check) valve for circuits you want isolated from supply-side dropouts. The manual drain suits an attended station bled on a schedule; automatic and differential-pressure drain codes exist for hard-to-reach mounts. The square MPa gauge is built in, thread can be ordered as G (BSPP) or NPT rather than PT, and the J code means you supply your own bracket. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

Airtac GFR Filter Regulator GFR400C10MJF1WK FAQ

AirTAC publishes flow for the G series as curves, not as a single rated number, so we do not quote one figure. Send us your required flow and working pressure and we will confirm the datasheet curve for this 400-size, 3/8 in unit against your application before you order.

The W code fits a 5 um element instead of the standard 40 um grade, and the K code adds a reverse (check) valve. Together they give finer filtration plus a checked downstream side on the same 400-size body with PT 3/8 in ports, manual drain, square MPa gauge and no bracket. Drop either code if you do not need that feature.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFR Filter Regulator GFR400C10MJF1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C10MJF1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.