The AirTAC GFR Filter Regulator GFR400C10MJNK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR400C10MJNK is an AirTAC GFR-series filter regulator: water and particulate filtration plus downstream pressure regulation built into a single body, with no lubricator. This 400-size unit carries a PT3/8 port, a manual-drain bowl in PC (polycarbonate), a standard 40 um filter element, no gauge and no mounting bracket, and the trailing K adds a built-in reverse (check) valve to the body; its detailed behaviour is covered in the datasheet, which we supply on request. The regulator set point is adjusted across 0.05-0.9 MPa (7-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part supplied through a distributor. The G series spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options that include differential-pressure, automatic or manual drains, 40 um or 5 um elements, G (BSPP) and NPT thread variants, and check-valve or no-check-valve configurations. AirTAC publishes flow for this series as characteristic curves rather than a single rating, so we confirm datasheet and flow figures against your application on request.
| Model | Airtac GFR Filter Regulator GFR400C10MJNK |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Feeding the hold-down cylinder of a small pneumatic press, the unit filters and regulates the supply air, and the built-in check valve suits circuits that need isolation from the supply side. The manual bowl drain is bled during maintenance windows.
As the point-of-use station on a manual assembly bench, it conditions the drop feeding air screwdrivers, small cylinders and jigs, with the regulator set to the tool circuit's working pressure and the bowl drained by hand at shift end.
Supplying quarter-turn pneumatic actuators on a plant valve manifold, the filter regulator keeps particle-laden plant air out of the actuator ports and lets technicians dial in the actuation pressure without touching the header.
Size 400 with a 3/8 inch port sits in the upper-middle of the G series range (200/300/400/600); step a size up or down if your line needs a larger or smaller port. The M code is a manual drain, which the operator empties by hand and which widens the regulator adjustment range to 0.05-0.9 MPa (7-130 psi) versus 0.15-0.9 MPa (20-130 psi) with automatic or differential-pressure drains. Choose this K variant when a reverse/check valve is wanted in the body, or the version without K otherwise. The standard element filters to 40 um, or pick the W variant for 5 um filtration. This N code has no gauge, thread is PT as standard with G (BSPP) and NPT as order options, and the J code omits the bracket. Flow is published as curves, not a single rated figure, so send us your line pressure and required flow and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the G series as characteristic curves rather than one rated figure, so we do not quote a single flow number. Tell us your line pressure and the flow your circuit needs and we will check the 3/8 in curve against the datasheet and confirm the result on request.
It denotes a built-in reverse (check) valve in the filter regulator body; the otherwise identical code without K has no check valve. Detailed behaviour is set out in the AirTAC datasheet, which we are happy to provide on request.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.