verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

Airtac GFR Filter Regulator GFR400C15AF1WK

The AirTAC GFR Filter Regulator GFR400C15AF1WK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$92.47 $98.45Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR400-15 drain, gauge and thread option on one page All GFR400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFR Filter Regulator GFR400C15AF1WK

The GFR400C15AF1WK is a genuine AirTAC G-series filter regulator combining three code options: the W 5 um fine-filtration element and a K reverse (check) valve, on a size 400 body with a 1/2 inch PT port. Water and fine particulate are removed, pressure is stepped down for the downstream circuit, and the check valve blocks backflow so the downstream set pressure holds when upstream supply dips - for example during compressor unloading. The automatic drain clears condensate from the PC (polycarbonate) bowl unattended, and an embedded square pressure gauge scaled in MPa shows the regulated pressure. With the automatic drain, the regulating range is 0.15-0.9 MPa (20-130 psi); maximum working pressure is 1.0 MPa (145 psi) and operating temperature is -5 to 70 C.

This is a genuine AirTAC part from a family spanning 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, plus drain-type, filter-grade, gauge-scale, thread and mounting options. AirTAC publishes flow capacity as curves rather than a single rating, so send us your line conditions and we will confirm the figures from the datasheet on request.

Airtac GFR Filter Regulator GFR400C15AF1WK Technical Specifications

ModelAirtac GFR Filter Regulator GFR400C15AF1WK
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFR Filter Regulator GFR400C15AF1WK

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the Airtac GFR Filter Regulator GFR400C15AF1WK Is Used

speed

High-cycle coating and dosing valves

Feeding fine-filtration-sensitive dosing and coating valves on a fast packaging line, with the check valve holding the regulated circuit steady while the compressor loads and unloads.

engineering

Test benches and calibration rigs

Supplying 5 um filtered, regulated air to test-bench actuators and calibration fixtures, where the check valve keeps the set pressure isolated from upstream dips during a test sequence.

shield

Protected circuits for precision grippers

Conditioning air to delicate gripper and clamp circuits on robotic handling cells, combining the 5 um element for fine cleanliness with the check valve to guard against reverse flow when main supply is dropped.

Is the Airtac GFR Filter Regulator GFR400C15AF1WK the Right Unit?

Pick this code when you need fine 5 um filtration and backflow protection in the same 1/2 inch, size 400 unit - the check valve is the difference from GFR400C15AF1W. Step to size 600 for larger ports and more flow, or down to 300/200 for compact takeoffs. The A suffix gives an automatic drain for unmanned installations; manual and differential-pressure drains are alternate codes. The embedded square gauge reads in MPa; other gauge scales, G or NPT threads and the no-bracket J option are catalogue choices.

Flow is published as curves, not a single rated number, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

Airtac GFR Filter Regulator GFR400C15AF1WK FAQ

AirTAC publishes filter regulator capacity as flow curves rather than a single rated figure, so we do not quote a number on the page. Share your line pressure, port size and downstream demand and we will confirm the right size from the datasheet on request.

W specifies the 5 um fine-filtration element in place of the standard 40 um, for downstream equipment sensitive to fine particles. K specifies a reverse (check) valve fitted in the unit, which blocks backflow and helps hold the downstream set pressure during upstream dips. The rest of the code - size 400, 1/2 inch PT port, automatic drain, embedded square MPa gauge - is unchanged.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFR Filter Regulator GFR400C15AF1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15AF1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.