verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

Airtac GFR Filter Regulator GFR400C15AJF1K

The AirTAC GFR Filter Regulator GFR400C15AJF1K is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$91.56 $97.52Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR400-15 drain, gauge and thread option on one page All GFR400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFR Filter Regulator GFR400C15AJF1K

The AirTAC GFR series filters and regulates compressed air in one body: a drain bowl with a replaceable element removes water and particulate, then an integrated regulator sets the downstream working pressure. The GFR400C15AJF1K is the size 400 frame with a 1/2 in PT (standard) port, automatic drain, the standard 40 um element, an embedded square pressure gauge reading in MPa, and a reverse (check) valve on the outlet that helps hold downstream pressure if the upstream supply dips. Maximum inlet pressure is 1.0 MPa (145 psi); with the automatic drain the regulation range is 0.15-0.9 MPa (20-130 psi), and the PC (polycarbonate) bowl works from -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The G series covers sizes 200, 300, 400 and 600 (larger sizes give larger ports and more flow), with drain, element-grade, gauge, thread and bracket options across the range; G (BSPP) and NPT threads are catalogue choices besides the standard PT. Flow performance is published as curves rather than a single rated figure, so ask us to confirm datasheet and sizing details for your application on request. Medium is compressed air only.

Airtac GFR Filter Regulator GFR400C15AJF1K Technical Specifications

ModelAirtac GFR Filter Regulator GFR400C15AJF1K
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFR Filter Regulator GFR400C15AJF1K

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the Airtac GFR Filter Regulator GFR400C15AJF1K Is Used

bolt

Pneumatic press and riveting cells

Regulating the supply to a pneumatic press or riveting cell, where the fitted check valve keeps the set pressure in the circuit if the upstream supply dips mid-cycle.

precision_manufacturing

Fixture clamping on machining lines

Setting clamp pressure on transfer-line fixtures; the reverse valve helps hold pressure at the clamps during brief upstream pressure drops so parts stay secured.

valve

Automated valve-actuator skids

Feeding quarter-turn pneumatic actuators on a process skid with clean, regulated air, while the check valve prevents backflow out of the actuator circuit.

Is the Airtac GFR Filter Regulator GFR400C15AJF1K the Right Unit?

Size 400 with a 1/2 in PT port sits at the upper-middle of the G range (200/300/400/600); step up or down a frame, or pick 3/4 in (20) or 1 in (25) ports, if your branch line demands it. Drains are offered as differential-pressure (default), automatic (this code) and manual; the automatic drain gives the 0.15-0.9 MPa (20-130 psi) regulation span. The K suffix adds the reverse (check) valve - choose it where a momentary upstream pressure drop must not dump the downstream circuit. The 40 um element is standard; the W suffix selects 5 um. Gauge scale, G or NPT thread and a bracket are orderable options; this code omits the bracket. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

Airtac GFR Filter Regulator GFR400C15AJF1K FAQ

AirTAC publishes G-series performance as flow curves rather than a single rated figure, so we do not quote one number. Share your working pressure and air demand and we will confirm the sizing from the datasheet on request.

K means a reverse (check) valve is fitted, so air flows one way through the unit and downstream pressure is not pushed back upstream if supply pressure falls. The same unit without the K is the standard version.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFR Filter Regulator GFR400C15AJF1K

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15AJF1K and will confirm price, stock and lead time — usually within 7-8 hours.