The AirTAC GFR Filter Regulator GFR400C15AJF1WK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR series filters and regulates compressed air in one body: a drain bowl with a replaceable element removes water and particulate, then an integrated regulator sets the downstream working pressure. The GFR400C15AJF1WK is the size 400 frame with a 1/2 in PT (standard) port, automatic drain, the optional 5 um element, an embedded square pressure gauge reading in MPa, and a reverse (check) valve that helps hold downstream pressure during upstream dips. Maximum inlet pressure is 1.0 MPa (145 psi); with the automatic drain the regulation range is 0.15-0.9 MPa (20-130 psi), and the PC (polycarbonate) bowl works from -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The G series covers sizes 200, 300, 400 and 600 (larger sizes give larger ports and more flow), with drain, element-grade, gauge, thread and bracket options across the range; G (BSPP) and NPT threads are catalogue choices besides the standard PT. Flow performance is published as curves rather than a single rated figure, so ask us to confirm datasheet and sizing details for your application on request. Medium is compressed air only.
| Model | Airtac GFR Filter Regulator GFR400C15AJF1WK |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Supplying pick-and-place robot grippers and ejector circuits, where the 5 um element protects small orifices and the check valve holds circuit pressure if the supply dips.
Point-of-use conditioning for automatic spray guns on a coating line: 5 um filtration ahead of the gun, with the check valve keeping line pressure stable through upstream dips.
Feeding a machine's pneumatic control manifold and pilot valves with clean, regulated air at a set pressure, protected against reverse flow out of the panel.
This code combines the two main options on the GFR400 frame: the W suffix selects the finer 5 um element over the standard 40 um grade, and the K suffix fits a reverse (check) valve so a momentary upstream pressure drop does not dump the downstream circuit - a common pairing where fine filtration and pressure hold are both needed. The 1/2 in PT port and size 400 frame sit in the upper-middle of the G range (200/300/400/600). Drains are offered as differential-pressure (default), automatic (this code) and manual; the automatic drain gives the 0.15-0.9 MPa (20-130 psi) regulation span. Gauge scale, G or NPT thread and a bracket are orderable options; this code omits the bracket. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
Flow for the G series is published as curves rather than a single rated figure, so we do not state one number. Give us your working pressure and air consumption and we will confirm the sizing from the datasheet on request.
This unit carries an embedded square gauge with an MPa scale (the F1 code in the model). Psi and bar scales are catalogue options, and an external round gauge is also available - tell us the scale your operators work in when ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.