AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

Airtac GFR Filter Regulator GFR400C15AJNK

The AirTAC GFR Filter Regulator GFR400C15AJNK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$85.86 $91.68Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR400-15 drain, gauge and thread option on one page All GFR400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFR Filter Regulator GFR400C15AJNK

The GFR400C15AJNK is an AirTAC G-series filter regulator: filtration and pressure regulation in one body, with the trailing K code adding a reverse (check) valve. This 400-size unit carries a 1/2in PT port, an automatic drain that clears condensate from the polycarbonate bowl unaided, and the standard 40 um filter element. No pressure gauge (N) and no mounting bracket (J) are fitted; outlet pressure adjusts over 0.15-0.9 MPa (20-130 psi) with a maximum inlet of 1.0 MPa (145 psi), and the temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part from the GFR family, which spans 200, 300, 400 and 600 sizes. Related catalogue options include a 5 um element, manual or differential-pressure drains, an embedded square or external round gauge, G (BSPP) or NPT threads and a fitting bracket. Flow is published as curves rather than a single rated figure, so we confirm datasheet numbers for you on request.

Airtac GFR Filter Regulator GFR400C15AJNK Technical Specifications

ModelAirtac GFR Filter Regulator GFR400C15AJNK
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFR Filter Regulator GFR400C15AJNK

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the Airtac GFR Filter Regulator GFR400C15AJNK Is Used

settings_input_component

Multi-branch valve manifold feed

Supplying a bank of directional valves on an automation manifold, where the fitted check valve keeps neighbouring branches from back-feeding through the regulator when one leg is vented.

conveyor_belt

Bottling line stopper stations

Filtered, regulated air for the stopper and gate cylinders along a bottling conveyor, with the automatic drain handling condensate during continuous shifts.

local_shipping

Trailer air-knife dust blow-off

Regulated air supply to the blow-off nozzles on a trailer or container cleaning station, where the check valve holds the downstream side if the upstream supply is isolated.

Is the Airtac GFR Filter Regulator GFR400C15AJNK the Right Unit?

Match size and port to the circuit's air demand: the 400 size with a 1/2in PT port sits between the 300 and 600 in the G-series, so move to a 300 or 600 frame if your mains differ. This code's automatic drain suits unattended plant; manual drain suits supervised stations, and differential-pressure drain is the default alternative. The element is the standard 40 um grade, with the finer 5 um option under GFR400C15AJNWK. The K code's check valve is the differentiator here: choose it where the downstream circuit must not feed back through the unit. Gauge (N) and bracket (J) are omitted, and PT is the standard thread with G (BSPP) and NPT as catalogue options. Because AirTAC publishes flow as curves, not one rated number, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

Airtac GFR Filter Regulator GFR400C15AJNK FAQ

AirTAC publishes G-series flow as characteristic curves rather than a single rated figure, and actual delivery depends on your upstream pressure and set pressure. Share your line pressure and required flow and we will confirm the datasheet figures for you before you order.

The K in GFR400C15AJNK means a reverse (check) valve is fitted so downstream air cannot flow back through the regulator; the plain GFR400C15AJN omits it. Choose the K version where an isolated or vented branch must not back-feed, and we can confirm the check-valve details from the datasheet on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFR Filter Regulator GFR400C15AJNK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15AJNK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.