The AirTAC GFR Filter Regulator GFR400C15F1 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
GFR400C15F1 is an AirTAC G-series filter regulator - filtration and pressure regulation combined in a single body. It strips water and particulate from the compressed air line and holds the downstream pressure at the setting you dial in. This configuration is the 400 frame with a PT1/2 port, the standard 40 um filter element, the differential-pressure drain (the default drain, which passes condensate as the pressure differential across it rises) and an embedded square pressure gauge scaled in MPa.
This is a genuine AirTAC part. Maximum working pressure is 1.0 MPa (145 psi), the standard regulating range with the differential-pressure drain is 0.15-0.9 MPa (20-130 psi), and the working temperature range is -5 to 70 C (non-freezing). The 400-size bowl is polycarbonate; the same GFR family spans 200, 300, 400 and 600 frames with automatic or manual drains, a 5 um (W) element, G (BSPP) or NPT threads, psi or bar gauge scales and a reverse-valve (K) option. G-series flow is published as curves rather than one rated number, so we confirm datasheet and sizing figures on request.
| Model | Airtac GFR Filter Regulator GFR400C15F1 |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Point-of-use supply for a 1/2 inch pneumatic press or riveting station: water and pipe scale are stripped from the plant air line and the press cylinder works at a fixed, repeatable setting.
Conditioning the main air drop on a cartoning or wrapping line, where the embedded MPa gauge lets operators check the machine supply pressure at a glance.
Regulated air for diverter gates and stop cylinders along a conveyor system, with the differential-pressure drain passing collected condensate while the line keeps running.
The 400 frame with its 1/2 inch port is the natural step for 1/2 inch machine drops; step down to GFR300 for 1/4-3/8 inch circuits or up to GFR600 where 3/4-1 inch lines demand more flow. The remaining choices on this family are all decodable from the code: drain type (differential-pressure standard, A automatic, M manual), element grade (40 um standard, W for 5 um), gauge scale (1 MPa, 2 psi, 3 bar), reverse valve (K), thread (PT standard, G or NPT to order) and the J no-bracket version. Because AirTAC publishes flow as pressure-drop curves, not a single rating, send us your line pressure and air demand and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series capacity as pressure-drop curves rather than a single rated flow figure, so quoting one number would be guesswork. Send us your working pressure and air demand and we will confirm the flow figures from the datasheet on request.
GFR identifies the filter-regulator family, 400 is the frame size, 15 is the 1/2 inch port code, and F1 is the embedded square gauge with an MPa scale. The absence of a drain letter gives the differential-pressure drain, and the absence of W gives the standard 40 um element. PT is the standard thread; G (BSPP) and NPT are catalogue options to order.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.