The AirTAC GFR Filter Regulator GFR400C15JC1WK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR400C15JC1WK is an AirTAC G-series filter regulator: one body that strips water and particulate from compressed air and holds downstream pressure steady. This 400-size configuration carries a 1/2 in PT port, a 5 um element for finer filtration than the standard 40 um grade, a differential-pressure drain, an external round pressure gauge scaled in MPa, and a built-in reverse (check) valve that keeps the set pressure from bleeding back. No mounting bracket is included with this code.
This is a genuine AirTAC part. The GFR filter-regulator family is offered in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in and thread options PT (standard), G (BSPP) or NPT; drain choices are differential-pressure, automatic or manual and the element is 40 um standard or 5 um (W). Flow for this series is published as curves rather than one rating, so we confirm datasheet figures on request.
| Model | Airtac GFR Filter Regulator GFR400C15JC1WK |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Conditioning the shop-air feed to a CNC machining center's pneumatic tool-changer and clamping circuits: clean, dry air at a set pressure before the machine's solenoid valves.
Feeding the pneumatic control valve bank on a bottling line, where the 5 um element helps keep fine particulate out of the valve spools and the regulator holds a steady setting.
Supplying filtered, regulated air to diverter and stopper cylinders on a packaging conveyor, with the check valve holding the set pressure against backfeed from the manifold.
Size 400 with a 1/2 in PT port suits lines whose air demand sits above what a 300-size, 3/8 in unit can pass; step up to 600 or down to 300 according to the port of your downstream equipment. The differential-pressure drain bleeds condensate as the pressure across the bowl changes, while automatic (A) and manual (M) variants are orderable on the same body. The 5 um (W) element is the right pick where finer dirt holding matters; 40 um remains the standard grade. Gauge options are the embedded square gauge or this external round gauge, with MPa (1), psi (2) or bar (3) scales; PT is the standard thread with G and NPT as orderable options, and the J code here means you should order a bracket separately.
Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as curves, not as a single rated figure, so we do not quote one number here. Send us your line pressure, downstream demand and allowable pressure drop and we will confirm the sizing from the GFR400C15 datasheet on request.
K indicates a reverse (check) valve is fitted, so air cannot flow back through the unit and the regulated setting is held. Codes without K have no check valve. The J in this code also means no mounting bracket is included - order one separately if you need panel or wall mounting.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.