AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

Airtac GFR Filter Regulator GFR400C15JNWK

The AirTAC GFR Filter Regulator GFR400C15JNWK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$75.42 $80.97Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR400-15 drain, gauge and thread option on one page All GFR400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFR Filter Regulator GFR400C15JNWK

GFR400C15JNWK is an AirTAC GFR-series filter regulator: water and particulate removal plus downstream pressure regulation in a single body. Compressed air passes a 5 um element, the finer of the two grades offered in the series, and the regulator holds a set pressure anywhere in the 0.15-0.9 MPa (20-130 psi) range that applies to the differential-pressure drain fitted here. Condensate collects in the polycarbonate bowl and is purged by the differential-pressure drain. The port is PT1/2, the standard thread for this series, with a maximum inlet pressure of 1.0 MPa (145 psi) and an operating temperature of -5 to 70 C (non-freezing). A reverse (check) valve is fitted, and this configuration carries no pressure gauge (code N) and no mounting bracket (code J).

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, a choice of differential-pressure, automatic or manual drain, 40 um or 5 um filtration, gauge options and G or NPT thread variants. AirTAC publishes flow for this series as curves rather than a single rating, so ask us to confirm sizing against your application - we can supply the datasheet on request.

Airtac GFR Filter Regulator GFR400C15JNWK Technical Specifications

ModelAirtac GFR Filter Regulator GFR400C15JNWK
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFR Filter Regulator GFR400C15JNWK

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the Airtac GFR Filter Regulator GFR400C15JNWK Is Used

precision_manufacturing

CNC machining centre air blast

Filtered, regulated air for chip-clearing nozzles and seal-air circuits on a machining centre, with the 5 um element helping keep fine jets clear and the check valve blocking backflow toward the supply.

science

Laboratory automation pilot valves

Steady point-of-use pressure for the small pilot valves and actuators on an automated analyser or sample-handling station, where fine particulate must stay out of narrow-bore piping.

factory

Packaging machine vacuum cups

Regulated air to the vacuum-cup and sealing-jaw circuits of a carton or blister wrapper, where the filter-regulator keeps water and debris away from the valve bank.

Is the Airtac GFR Filter Regulator GFR400C15JNWK the Right Unit?

Size 400 with a 1/2 in PT port sits in the upper-middle of the GFR range (sizes 200-600, ports 1/8-1 in); step up or down a size if your line demand calls for it, and we will check the published flow curve against your application before you order. This configuration carries a differential-pressure drain, a 5 um element, a check valve, and no gauge or bracket; gauged and bracketed variants exist in the coded series, and G or NPT threads are catalogue options. Remember the regulation span for the differential-pressure drain is 0.15-0.9 MPa (20-130 psi).

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

Airtac GFR Filter Regulator GFR400C15JNWK FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number on the page. Send us your inlet pressure, set pressure and expected air demand, and we will confirm sizing from the datasheet on request.

The differential-pressure drain purges the bowl automatically when the pressure drop across the element indicates a build-up of condensate. An automatic drain (code A) dumps condensate continuously without that trigger, and a manual drain (code M) needs to be opened by hand. Pick based on how wet your supply air is and how often someone can attend the unit.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFR Filter Regulator GFR400C15JNWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15JNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.