verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

Airtac GFR Filter Regulator GFR400C15MF1WK

The AirTAC GFR Filter Regulator GFR400C15MF1WK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$82.02 $87.75Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR400-15 drain, gauge and thread option on one page All GFR400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFR Filter Regulator GFR400C15MF1WK

The AirTAC GFR series combines water and particulate filtration with pressure regulation in one body. The GFR400C15MF1WK is the 400 size with a PT1/2 port, a manual drain bowl, a 5 um element for finer filtration than the standard 40 um grade, an embedded square pressure gauge on an MPa scale, and a built-in reverse (check) valve that holds the downstream setting if the upstream supply is shut off. Maximum inlet pressure is 1.0 MPa (145 psi), the manual-drain regulation range is 0.05-0.9 MPa (7-130 psi), and the polycarbonate bowl suits ambient temperatures from -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The G series spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, offered as filters, regulators, lubricators, filter regulators and full three-unit F.R.L. sets, with automatic, manual or differential-pressure drains, 40 um or 5 um elements, G (BSPP) or NPT thread options and optional brackets. Flow is published as curves rather than a single rating, so we confirm exact figures from the datasheet on request.

Airtac GFR Filter Regulator GFR400C15MF1WK Technical Specifications

ModelAirtac GFR Filter Regulator GFR400C15MF1WK
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFR Filter Regulator GFR400C15MF1WK

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the Airtac GFR Filter Regulator GFR400C15MF1WK Is Used

precision_manufacturing

CNC fixture clamping circuit

Regulate the supply to power clamps on a machining-centre fixture, holding one steady set pressure for the clamping valves while the 5 um element keeps fine particulate out of the pilot circuit.

factory

Case palletizer grippers

Feed the gripper cylinders and vacuum generators on a case palletizing line; the built-in check valve holds the regulated pressure at the gripper circuit when the main air is isolated upstream.

conveyor_belt

Bottling line divert gates

Supply stop-and-divert gates on a bottling conveyor, where the manual drain lets an operator bleed accumulated water from the bowl as part of the start-of-shift walk-round.

Is the Airtac GFR Filter Regulator GFR400C15MF1WK the Right Unit?

Move up to the 400 size when the circuit needs a 1/2 inch port or when your flow sits near the top of the size 300 curve - send us the duty and we will confirm sizing against the curve before you order. Pick the manual drain where an operator walks the line and can bleed the bowl at shift start, or where the lowest regulation floor matters: manual drain allows 0.05-0.9 MPa (7-130 psi) versus 0.15-0.9 MPa (20-130 psi) with automatic or differential-pressure drains. The 5 um (W) element is the choice for pilot valves and cylinders that tolerate less particulate; the embedded square gauge reads in MPa. Thread is PT as standard, with G (BSPP) and NPT as catalogue options to order, and this code includes the mounting bracket.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

Airtac GFR Filter Regulator GFR400C15MF1WK FAQ

AirTAC publishes flow for the G series as performance curves rather than a single rated figure, so we do not quote one number on the page. Tell us your line pressure and required flow and we will confirm sizing from the datasheet on request before you order.

A manual drain means someone bleeds the bowl by hand, which suits attended machines and gives the widest regulation range: 0.05-0.9 MPa (7-130 psi) versus 0.15-0.9 MPa (20-130 psi) for automatic or differential-pressure drains. Choose automatic if the unit sits in an unattended spot.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFR Filter Regulator GFR400C15MF1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15MF1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.