verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

Airtac GFR Filter Regulator GFR400C15MJF1W

The AirTAC GFR Filter Regulator GFR400C15MJF1W is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$69.77 $75.19Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR400-15 drain, gauge and thread option on one page All GFR400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFR Filter Regulator GFR400C15MJF1W

GFR400C15MJF1W is an AirTAC GFR400 filter regulator: filtration and pressure regulation in one body, ordered with the fine 5 um filter element (W suffix) instead of the standard 40 um grade. This configuration also carries a manual drain, an embedded square pressure gauge with MPa scale, and no mounting bracket. The port is PT1/2 (1/2 in PT thread, the standard for this code) and the bowl is polycarbonate (PC) at size 400. Regulator setting range with the manual drain is 0.05-0.9 MPa (7-130 psi); maximum working pressure is 1.0 MPa (145 psi) and operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family covers sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, G (BSPP) and NPT thread options, a choice of differential-pressure, automatic or manual drains, and 40 um or 5 um elements. Flow is published as curves rather than a single rating, so we confirm the datasheet and sizing on request.

Airtac GFR Filter Regulator GFR400C15MJF1W Technical Specifications

ModelAirtac GFR Filter Regulator GFR400C15MJF1W
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFR Filter Regulator GFR400C15MJF1W

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the Airtac GFR Filter Regulator GFR400C15MJF1W Is Used

science

Laboratory instrument air

Feeds pneumatic valves and actuated accessories on lab and pilot-plant equipment, where the 5 um element protects sensitive components from fine particulate.

view_module

Electronics assembly workstations

Supplies bench tools and pick-and-place assist cylinders at electronics workstations, with finer filtration suited to clean, dry air at the point of use.

valve

Food filling machine actuation

Conditions the air driving filling-valve actuators and clamp cylinders on a filling machine, combining steady regulated pressure with fine particle removal.

Is the Airtac GFR Filter Regulator GFR400C15MJF1W the Right Unit?

Choose the W suffix when the downstream equipment needs finer particle control than the standard 40 um element provides; note that a finer grade loads up faster, so the drain routine matters more. Size 400 with a 1/2 in PT port serves medium-to-high demand - verify the size against the published flow curve for your duty point. The manual drain widens the setting range to 0.05-0.9 MPa (7-130 psi), versus 0.15-0.9 MPa (20-130 psi) on automatic or differential-drain versions. Square or round gauges are available in MPa, psi or bar scales; G (BSPP) and NPT threads and a bracket are catalogue options, and the K suffix adds a check valve if needed. Flow is published as curves, not a single rating, so ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

Airtac GFR Filter Regulator GFR400C15MJF1W FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so no flow number is stated here. Give us your pressure and demand and we will confirm the datasheet sizing on request, including any effect of the finer element on your duty point.

W (5 um) is for point-of-use protection of finer components such as instrument valves, spray equipment or precision actuators. The blank standard is 40 um for general plant air. Both grades are orderable across the whole GFR range by adding or omitting the W suffix.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFR Filter Regulator GFR400C15MJF1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15MJF1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.