verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

Airtac GFR Filter Regulator GFR400C15MJNWK

The AirTAC GFR Filter Regulator GFR400C15MJNWK is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$75.42 $80.97Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GFR400-15 drain, gauge and thread option on one page All GFR400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GFR Filter Regulator GFR400C15MJNWK

The GFR400C15MJNWK is an AirTAC GFR400 filter regulator: a filter and a pressure regulator in one body with a single polycarbonate drain bowl. It is sized for 1/2in PT ports, and the trailing K suffix adds a check valve to the configuration. The M suffix specifies manual drainage, so the bowl is emptied by hand on a maintenance schedule, and the W suffix fits the 5 um filter element instead of the 40 um standard grade. No gauge is fitted (N suffix) and no mounting bracket is included (J suffix). Regulating range with manual drainage is 0.05-0.9 MPa (7-130 psi) against a maximum inlet pressure of 1.0 MPa (145 psi); working temperature is -5 to 70 C.

This is a genuine AirTAC part. The same 400 frame is available across the G series in 200, 300, 400 and 600 sizes with ports from 1/8in to 1in, and can be ordered with automatic or differential-pressure drainage, the 40 um element, a gauge, a mounting bracket, G (BSPP) or NPT threads, with or without the check valve. Flow is published as performance curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.

Airtac GFR Filter Regulator GFR400C15MJNWK Technical Specifications

ModelAirtac GFR Filter Regulator GFR400C15MJNWK
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GFR Filter Regulator GFR400C15MJNWK

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the Airtac GFR Filter Regulator GFR400C15MJNWK Is Used

build

Clamping fixture line in a machining cell

Regulated, filtered air to the swing clamps on a CNC machining cell fixture, taken from a 1/2in drop, with the check valve included in the configuration as coded.

conveyor_belt

Sorting gate actuation

Air prep for the diverter and stopper cylinders on a parcel sorting conveyor, where the unit sits at the head of each 1/2in branch line.

precision_manufacturing

Pneumatic press counterbalance supply

Filtered, regulated air to the counterbalance and ejection cylinders of a small pneumatic press, with manual drainage fitting a pressside attended each shift.

Is the Airtac GFR Filter Regulator GFR400C15MJNWK the Right Unit?

Step through the G series frames (200, 300, 400, 600) to match air demand; this unit carries the 1/2in PT port in the 400 frame. The trailing K adds the check valve - order this suffix when your circuit calls for one, or the same code without K when it does not. Manual drainage is the right choice where an operator drains the bowl on schedule; automatic and differential-pressure drains exist on the same frame. The W suffix gives the 5 um element against the standard 40 um grade, and a gauge with MPa, psi or bar scale can be added since none is fitted. Threads are PT as standard with G (BSPP) and NPT as ordering options; the J suffix omits the bracket. Because rated flow is published as curves and not a single number, send us your flow requirement and we will confirm sizing against the AirTAC datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

Airtac GFR Filter Regulator GFR400C15MJNWK FAQ

Flow for the GFR series is published as performance curves rather than a single rated figure, so there is no one number we can honestly quote here. Send us your line pressure and air demand and we will confirm the sizing against the datasheet on request.

The trailing K specifies that a check valve is fitted in this unit. The same 400 frame, port, manual drain and 5 um element are available without the K suffix if your circuit does not call for a check valve.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GFR Filter Regulator GFR400C15MJNWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15MJNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.