verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

AirTAC GFR300C08ALC2WG Filter Regulator G1/4 5 um

The AirTAC AirTAC GFR300C08ALC2WG Filter Regulator G1/4 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$58.22 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GFR300C08ALC2WG Filter Regulator G1/4 5 um

The GFR300C08ALC2WG is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This unit is built on the 300 size with a G1/4 (BSPP) port, a 5 um filter element (code W), an automatic drain, and the low-pressure regulator type. A round pressure gauge with a psi scale is fitted, the bowl is metal, and a mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options that include differential-pressure, automatic or manual drains, a 40 um standard or 5 um (W) element, embedded square or external round gauges with MPa, psi or bar scales, G or NPT threads in place of the PT standard, and a no-bracket variant. Flow is published as curves rather than a single rating, so ask us to confirm sizing figures from the datasheet for your application.

AirTAC GFR300C08ALC2WG Filter Regulator G1/4 5 um Technical Specifications

ModelAirTAC GFR300C08ALC2WG Filter Regulator G1/4 5 um
SeriesGFR300 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFR300C08ALC2WG Filter Regulator G1/4 5 um

GFR300G-series filter regulator, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · See datasheet · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-C0 (two-unit set)

Where the AirTAC GFR300C08ALC2WG Filter Regulator G1/4 5 um Is Used

valve

Low-pressure glue or coating circuit

Placed ahead of the spray valves on a low-pressure adhesive or coating line, it filters the air and holds a reduced, stable supply pressure - the job the low-pressure regulator type on this unit is built for.

precision_manufacturing

CNC fixture clamping circuit

Feeding the clamping cylinders on a machining centre, it strips water and 5 um-scale particulate from the shop air and lets the setter read and adjust clamp pressure at the machine on the fitted psi gauge.

conveyor_belt

Packaging line air prep drop

Mounted at the drop feeding the cylinders and actuators on a packaging conveyor, the automatic drain expels collected condensate on its own so the line keeps running without a manual bowl check.

Is the AirTAC GFR300C08ALC2WG Filter Regulator G1/4 5 um the Right Unit?

Choose the size step (200/300/400/600) and port to match the air demand of your circuit - the 300 size here carries a 1/4 inch port. Drain type is a real choice: differential-pressure (default), automatic (this unit) or manual. Filter grade is 40 um standard or 5 um with code W - this unit carries the 5 um element. An embedded square gauge is standard and an external round gauge is optional, with MPa, psi or bar scales; this unit has the round gauge with a psi scale. Thread is PT as standard with G and NPT as order options - this unit is G. Brackets are optional; this one includes one. Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm sizing from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

AirTAC GFR300C08ALC2WG Filter Regulator G1/4 5 um FAQ

AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and air demand and we will confirm the sizing from the datasheet on request.

The drain choice across the family is differential-pressure (default), automatic or manual. The automatic drain on this GFR300C08ALC2WG expels collected condensate without anyone opening the bowl, which suits unattended or hard-to-reach installations; manual and differential-pressure drains remain available on other variants.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GFR300C08ALC2WG Filter Regulator G1/4 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR300C08ALC2WG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.