verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GPF400 · Mist Separator

Airtac GPF Oil Mist Separator GPF40010AJD

Genuine AirTAC mist separator, order code GPF40010AJD from the GPF400 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.

  • Port3/8" (10)
  • Bowl · drainPC bowl · Automatic drain (A)
  • Configuration0.01 µm element (D) · No bracket (J) · PT thread
  • Port3/8" (10), 1/2" (15)
  • ThreadPT (standard)
  • Filter element0.3 µm (M) / 0.01 µm (D), 99.9% efficiency
$56.98 $64.48Save 11%
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GPF400 port, bowl/drain and configuration on one page All GPF400 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GPF Oil Mist Separator GPF40010AJD

Ordering GPF40010AJD gives you the AirTAC GPF400 mist separator with the J option, meaning the mounting bracket is deliberately omitted. Everything else on the air path stays the GP-series standard: a 3/8 inch (size 10) PT port pair, a PC bowl fitted with the A automatic drain, and the D element that removes oil mist down to 0.01 um at 99.9 percent efficiency.

Skipping the bracket matters for builders who already have their own plates, panels or manifold spacing. The unit still operates across 0.15 to 1.0 MPa (20 to 145 psi), survives 1.5 MPa (215 psi) proof pressure, works from -5 to +70 C, and its 89 cc bowl drains itself, so you can integrate it inline wherever your own mounting solution exists.

Airtac GPF Oil Mist Separator GPF40010AJD Technical Specifications

Order codeGPF40010AJD
ProductMist Separator
Port3/8" (10)
Bowl · drainPC bowl · Automatic drain (A)
Configuration0.01 µm element (D) · No bracket (J) · PT thread
Port3/8" (10), 1/2" (15)
ThreadPT (standard)
Filter element0.3 µm (M) / 0.01 µm (D), 99.9% efficiency
Drain bowl capacity89 cc
Weight620 g / 627 g
FluidAir
Operating pressure0.15 – 1.0 MPa (20 – 145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature-5 to +70 °C (no freezing)
Rated flowM: 1100 L/min · D: 600 L/min (inlet 0.7 MPa, outlet 0.5 MPa)

Source: AirTAC Products Catalog 2026A (p.240, PDF01-P0242), GPF ordering code and specifications.

How to choose

This is the bracket-free twin of GPF40010AD: same 3/8 inch PT ports, same PC bowl with automatic drain, same 0.01 um D element, but option J removes the bracket from the package. If you need the unit to stand on its own, order the AD code instead. If your application passes more than about 600 L/min (inlet 0.7 MPa, outlet 0.5 MPa), the M-element GPF40010AJM flows 1100 L/min but filters only to 0.3 um, and 1/2 inch piping calls for the size 15 code.

Applications

precision_manufacturing

OEM machine integration

Built into custom machinery where the OEM supplies its own mounting plate, so option J avoids a bracket that would only be discarded.

straighten

Inline pipework installation

Fitted directly into a rigid 3/8 inch PT air line between fixed points, with the automatic drain handling condensate from the 89 cc PC bowl.

sensors

Sensitive downstream equipment

Feeding pneumatic sensors and precision regulators that need the 0.01 um, 99.9 percent efficiency element, on a line already structurally supported.

FAQ

What are the key figures for the GPF40010AJD?

Port 3/8 inch (size 10), PT thread; PC bowl with automatic drain (A), 89 cc capacity; D element 0.01 um at 99.9 percent efficiency; rated flow 600 L/min (inlet 0.7 MPa, outlet 0.5 MPa); operating pressure 0.15 to 1.0 MPa (20 to 145 psi); proof pressure 1.5 MPa (215 psi); temperature -5 to +70 C (no freezing); fluid air; mounting bracket NOT included (option J).

What exactly does the J in GPF40010AJD change?

Only the mounting hardware. Per the GPF400 ordering code, blank means a bracket is included and J means without bracket; ports, PC bowl, automatic drain and the 0.01 um D element are identical to the bracketed version. If your layout cannot support the body on its own, choose the AD code instead - or pair this unit into a GA-series two- or three-unit set that provides the structure.