Genuine AirTAC mist separator, order code GPF40010JD from the GPF400 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
GPF40010JD is the AirTAC GPF400 GP-series mist separator ordered with two defining choices in its code: the J configuration, meaning no mounting bracket is supplied, and the D element with 0.01 um removal at 99.9% efficiency. The port is 3/8 inch (10) with PT thread, the drain is the standard differential-plus-manual type, and condensate collects in the 89 cc PC bowl. Rated flow is 600 L/min at an inlet of 0.7 MPa and an outlet of 0.5 MPa, the value the catalog gives for the finer D element.
The unit operates on 0.15 to 1.0 MPa (20 to 145 psi) with 1.5 MPa (215 psi) proof pressure and a -5 to +70 C range, no freezing. Omitting the bracket makes sense where the separator hangs directly on the air line, is panel-built, or forms part of a GA-series two- or three-unit set rather than standing on its own foot.
| Order code | GPF40010JD |
|---|---|
| Product | Mist Separator |
| Port | 3/8" (10) |
| Bowl · drain | PC bowl · Differential + manual drain |
| Configuration | 0.01 µm element (D) · No bracket (J) · PT thread |
| Port | 3/8" (10), 1/2" (15) |
|---|---|
| Thread | PT (standard) |
| Filter element | 0.3 µm (M) / 0.01 µm (D), 99.9% efficiency |
| Drain bowl capacity | 89 cc |
| Weight | 620 g / 627 g |
| Fluid | Air |
| Operating pressure | 0.15 – 1.0 MPa (20 – 145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature | -5 to +70 °C (no freezing) |
| Rated flow | M: 1100 L/min · D: 600 L/min (inlet 0.7 MPa, outlet 0.5 MPa) |
Source: AirTAC Products Catalog 2026A (p.240, PDF01-P0242), GPF ordering code and specifications.
GPF40010JD is the bracket-free twin of GPF40010D: same 3/8 inch PT port, PC bowl, differential-plus-manual drain and 0.01 um element, but the J option removes the mounting bracket, so plan your own fixing. If you want automatic condensate removal, order the A drain variant instead; for the coarser 0.3 um element and its higher 1100 L/min flow, look at the M versions of the 10 port.
Slotting into GA two- or three-unit combinations removes the need for a standalone bracket, since the set provides the shared mounting.
Suspending the separator directly on a 3/8 inch PT air line in machine frames or enclosures, where the J code avoids an unused bracket on the body.
0.01 um, 99.9% efficient filtration ahead of conveyor control valves, with condensate managed by the differential-plus-manual drain during scheduled checks.
Port 3/8 inch (10), PT thread standard; PC bowl with 89 cc capacity, differential plus manual drain; 0.01 um D element at 99.9% efficiency; rated flow 600 L/min at inlet 0.7 MPa and outlet 0.5 MPa; operating pressure 0.15 to 1.0 MPa (20 to 145 psi); proof pressure 1.5 MPa (215 psi); temperature -5 to +70 C, no freezing; J option means no bracket is included.
Only the mounting: the J in GPF40010JD means the unit is supplied without a bracket, while GPF40010D includes one. Filtration, drain type, bowl and port specification are unchanged, so select JD when your installation provides its own fixing or when the separator is built into a GA-series combination set.