verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GPF400 · Mist Separator

Airtac GPF Oil Mist Separator GPF400C10M

Genuine AirTAC mist separator, order code GPF400C10M from the GPF400 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.

  • Port3/8" (10)
  • Bowl · drainMetal bowl (C) · Differential + manual drain
  • Configuration0.3 µm element (M) · With bracket · PT thread
  • Port3/8" (10), 1/2" (15)
  • ThreadPT (standard)
  • Filter element0.3 µm (M) / 0.01 µm (D), 99.9% efficiency
$55.80 $63.30Save 11%
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GPF400 port, bowl/drain and configuration on one page All GPF400 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GPF Oil Mist Separator GPF400C10M

GPF400C10M is the free-standing version of the 3/8 in. GP-series mist separator: because the code carries no J suffix, a mounting bracket is included, so the unit can be fixed directly to a panel, machine frame or prep-line backplate. Inside is the M element, filtering oil mist and particles to 0.3 um at 99.9% efficiency with a rated flow of 1100 L/min (inlet 0.7 MPa, outlet 0.5 MPa).

The code reads as C = metal bowl, 10 = 3/8 in. port with PT thread standard, M = 0.3 um element, and blank drain position = differential plus manual. The metal bowl holds 89 cc of condensate and the unit weighs 620 g. It runs on 0.15 to 1.0 MPa (20 to 145 psi) with 1.5 MPa (215 psi) proof pressure across -5 to +70 C (no freezing), and it can also join GA-series two- or three-unit combinations when you expand the prep stack later.

Airtac GPF Oil Mist Separator GPF400C10M Technical Specifications

Order codeGPF400C10M
ProductMist Separator
Port3/8" (10)
Bowl · drainMetal bowl (C) · Differential + manual drain
Configuration0.3 µm element (M) · With bracket · PT thread
Port3/8" (10), 1/2" (15)
ThreadPT (standard)
Filter element0.3 µm (M) / 0.01 µm (D), 99.9% efficiency
Drain bowl capacity89 cc
Weight620 g / 627 g
FluidAir
Operating pressure0.15 – 1.0 MPa (20 – 145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature-5 to +70 °C (no freezing)
Rated flowM: 1100 L/min · D: 600 L/min (inlet 0.7 MPa, outlet 0.5 MPa)

Source: AirTAC Products Catalog 2026A (p.240, PDF01-P0242), GPF ordering code and specifications.

How to choose

GPF400C10M differs from GPF400C10JM only by the bracket: same metal bowl, same 3/8 in. PT port, same 0.3 um element and 1100 L/min flow, but this code mounts on its own while JM is meant for pipework- or GA-set-supported builds. Move to GPF400C10JD if you need the 0.01 um element, to the 15 code for a 1/2 in. line, or to the N and PC bowl variants if a metal bowl is unnecessary.

Applications

vertical_align_center

Panel-mounted FRL additions

The included bracket lets the separator sit alongside regulators and gauges on a prep panel, adding 0.3 um coalescing filtration to an existing 3/8 in. line.

forklift

Material-handling equipment air

Metal bowl construction suits the vibration and washdown exposure of forklift and dock equipment, with the differential plus manual drain emptied at service checks.

engineering

Machine-building OEM circuits

Builders can bracket-mount the unit inside a control cabinet frame and later extend the same foot pattern into a GA-series combined unit without redesign.

FAQ

What are the key figures of the GPF400C10M?

3/8 in. PT port, 0.3 um M element at 99.9% efficiency, rated flow 1100 L/min (inlet 0.7 MPa, outlet 0.5 MPa), operating pressure 0.15 to 1.0 MPa (20 to 145 psi), proof pressure 1.5 MPa (215 psi), temperature -5 to +70 C, 89 cc metal bowl, weight 620 g, differential plus manual drain, mounting bracket included.

What does the bracket in GPF400C10M give me over GPF400C10JM?

The J suffix in GPF400C10JM means no bracket is supplied, so that version depends on its pipework or a GA combination for support. GPF400C10M omits the J, so the bracket ships with the unit and it can be secured to a panel or frame independently; all filtration and flow figures are otherwise identical.