Genuine AirTAC mist separator, order code GPF400C15AD from the GPF400 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The GPF400C15AD pairs the GP-series mist separator body with the finest filtration option in the range: a 0.01 um coalescing element rated 99.9 percent efficient. Because the D element is the most thorough grade, its rated flow is 600 L/min at 0.7 MPa inlet and 0.5 MPa outlet, so lines needing very clean air but modest flow suit this code best. The 1/2 inch PT ports fit standard tapered pipe threads, and the unit works from 0.15 to 1.0 MPa (20 to 145 psi) with a 1.5 MPa (215 psi) proof pressure.
Two options are spelled out directly in the order code: C selects the metal bowl over PC or nylon, and A adds an automatic drain that empties the 89 cc bowl without manual intervention. A mounting bracket is included unless the code carries J, and PT thread is standard with G and T variants for other standards.
| Order code | GPF400C15AD |
|---|---|
| Product | Mist Separator |
| Port | 1/2" (15) |
| Bowl · drain | Metal bowl (C) · Automatic drain (A) |
| Configuration | 0.01 µm element (D) · With bracket · PT thread |
| Port | 3/8" (10), 1/2" (15) |
|---|---|
| Thread | PT (standard) |
| Filter element | 0.3 µm (M) / 0.01 µm (D), 99.9% efficiency |
| Drain bowl capacity | 89 cc |
| Weight | 620 g / 627 g |
| Fluid | Air |
| Operating pressure | 0.15 – 1.0 MPa (20 – 145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature | -5 to +70 °C (no freezing) |
| Rated flow | M: 1100 L/min · D: 600 L/min (inlet 0.7 MPa, outlet 0.5 MPa) |
Source: AirTAC Products Catalog 2026A (p.240, PDF01-P0242), GPF ordering code and specifications.
Choose this code when you need the D element (0.01 um) with automatic draining in a metal bowl on a 1/2 inch line. If your flow demand is higher and 0.3 um filtration is sufficient, the M-element GPF400C15AD's sibling GPF400C15AJM or bracketed GPF400C15AM passes up to 1100 L/min instead of 600 L/min. For PC or nylon bowls, look to the blank-bowl or N codes such as GPF400N15AD, and for G or NPT threads pick the G or T suffix versions.
The 0.01 um element at 99.9 percent efficiency removes oil mist ahead of measuring instruments and pneumatic sensors that cannot tolerate oily carryover.
The automatic drain (A option) continuously empties the 89 cc metal bowl, so the filter keeps working through long shifts without an operator draining it by hand.
Mounted on a 1/2 inch PT supply with the included bracket, the separator shields control valves and actuators from fine particles within the -5 to +70 C (no freezing) window.
Port 1/2 inch, PT thread; element D = 0.01 um at 99.9 percent efficiency; rated flow 600 L/min (inlet 0.7 MPa, outlet 0.5 MPa); operating pressure 0.15 to 1.0 MPa (20 to 145 psi); proof pressure 1.5 MPa (215 psi); bowl capacity 89 cc; metal bowl with automatic drain; bracket included; temperature -5 to +70 C, no freezing.
The C option selects a metal bowl, chosen over PC or nylon where impact resistance matters, and the A option means condensate drains automatically instead of requiring the standard differential plus manual drain routine, so the 89 cc bowl is emptied without operator action.