Genuine AirTAC filter regulator, order code GTFR20006L from the GTFR200 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The GTFR20006L is the low-pressure, fully equipped version of the AirTAC GTFR200 filter regulator. Its L suffix sets a regulated range of 0.15 to 0.4 MPa (20 to 58 psi), well below the standard type, and the 06 body gives a 1/8 in PT port. Air passes through the standard 40 um element into a short PC bowl, where condensate is removed by the differential plus manual drain, and the compact GT200 footprint suits machines where a full-size GA200 unit will not fit.
This code carries no J, N, W, G or T suffixes, so everything standard stays on board: the pressure gauge (reading MPa/psi) is fitted, the mounting bracket is included, the element is 40 um, and the threads are PT. You only need a regulator and a line fitting to put it to work.
| Order code | GTFR20006L |
|---|---|
| Product | Filter Regulator |
| Port | 1/8" (06) |
| Type · gauge | Low-pressure (L) · With gauge (MPa/psi) |
| Configuration | With bracket · 40 µm element · PT thread |
| Port | 1/8" (06), 1/4" (08) |
|---|---|
| Thread | PT (standard) |
| Filter element | 40 µm (standard), 5 µm (W) |
| Bowl | Short PC bowl |
| Drain | Differential + manual |
| Fluid | Air |
| Low-pressure (L) version | 0.15 – 0.4 MPa (20 – 58 psi) |
Source: AirTAC Products Catalog 2026A (p.235, PDF01-P0237), GT200 ordering code and specifications.
Choose GTFR20006L when your line is 1/8 in and your process runs at low pressure. If your circuit must hold its downstream setting when upstream air is shut off, step up to GTFR20006LJK, which adds a check valve. For cleaner air, order the W variant with the 5 um element instead of the standard 40 um. If you mount the unit on your own plate or panel, GTFR20006LJ omits the bracket, and GTFR20008L is the equivalent for a 1/4 in line. The standard-pressure GTFR20006S covers the normal range if 0.15 to 0.4 MPa is too low.
Bench leak and functional test stations often need a stable supply far below normal line pressure; the L range of 0.15 to 0.4 MPa (20 to 58 psi) is set directly on the fitted gauge.
Sealing, counting and conveying heads in packaging lines run on soft regulated air from a 1/8 in take-off, with the 40 um element protecting the downstream valves.
The included bracket lets you fix the short PC bowl unit beside the machine, and the differential plus manual drain clears accumulated condensate during operator rounds.
Port: 1/8 in (06), PT thread standard. Type: low-pressure L, regulated range 0.15 to 0.4 MPa (20 to 58 psi). Element: 40 um standard. Bowl: short PC with differential plus manual drain. Gauge: included. Bracket: included. Fluid: air.
L selects the low-pressure version of the GTFR200. Instead of the standard regulated range, it regulates 0.15 to 0.4 MPa (20 to 58 psi), which suits circuits that must never see full line pressure. Port, element and bowl behaviour stay as in the standard unit.