Genuine AirTAC filter regulator, order code GTFR20006LJ from the GTFR200 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
GTFR20006LJ is the AirTAC GTFR200 low-pressure filter regulator ordered without its mounting bracket, which is exactly what the J suffix means in the GT200 ordering code. The 06 body has a 1/8 in PT port and the L type regulates 0.15 to 0.4 MPa (20 to 58 psi), while the fitted pressure gauge shows MPa and psi. Air is filtered by the standard 40 um element and condensate leaves the short PC bowl through the differential plus manual drain.
Because the bracket is deleted, this code is aimed at builders who fasten the regulator their own way: screwed directly into a manifold face, clamped to a machine frame or fixed inside a control cabinet. Everything else remains the standard configuration, so ordering it keeps the gauge and the 40 um element without paying for hardware you will discard.
| Order code | GTFR20006LJ |
|---|---|
| Product | Filter Regulator |
| Port | 1/8" (06) |
| Type · gauge | Low-pressure (L) · With gauge (MPa/psi) |
| Configuration | No bracket (J) · 40 µm element · PT thread |
| Port | 1/8" (06), 1/4" (08) |
|---|---|
| Thread | PT (standard) |
| Filter element | 40 µm (standard), 5 µm (W) |
| Bowl | Short PC bowl |
| Drain | Differential + manual |
| Fluid | Air |
| Low-pressure (L) version | 0.15 – 0.4 MPa (20 – 58 psi) |
Source: AirTAC Products Catalog 2026A (p.235, PDF01-P0237), GT200 ordering code and specifications.
Order GTFR20006LJ when you have your own fixing method and do not want the standard bracket. If you need a wall or machine-frame mount, take GTFR20006L, which ships with the bracket included. The same low-pressure 1/8 in unit with a check valve added is GTFR20006LJK. For a 1/4 in port use GTFR20008L or its bracketless GTFR20008LJ, for a 5 um element add W to the code, and for normal pressure ranges use the S type instead of L.
Threaded straight into a valve manifold inlet with PT threads, the 1/8 in body filters and regulates low-pressure pilot air without needing a separate bracket.
Inside an electrical or pneumatic cabinet the compact GT200 body is fixed to the enclosure structure, and the fitted gauge stays readable through the door window.
Replacing a failed low-pressure regulator on a legacy machine is simpler when the new unit is screwed into the existing port and the old mounting hardware is reused.
Port: 1/8 in (06), PT thread standard. Type: low-pressure L, regulated range 0.15 to 0.4 MPa (20 to 58 psi). Element: 40 um standard. Bowl: short PC with differential plus manual drain. Gauge: included. Bracket: not included (J code). Fluid: air.
J means without bracket: the GTFR20006LJ arrives with no mounting bracket, while the same unit without J includes one. Everything else in the configuration is unchanged, so the gauge, 40 um element, short PC bowl and 1/8 in PT port are all as standard.