Genuine AirTAC filter regulator, order code GTFR20006LJNK from the GTFR200 range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The AirTAC GTFR20006LJNK is a GT200-series filter regulator with the K option, which adds a check valve to a 1/8 in (06), PT-threaded unit. It is the low-pressure L type, regulating 0.15 - 0.4 MPa (20 - 58 psi), and cleans air with the standard 40 um element inside a short PC bowl drained by differential plus manual action.
The check valve is what sets this code apart: it helps hold downstream air in the circuit when the upstream supply dips, which matters in processes where a momentary pressure loss would spoil the result. N deletes the gauge and J deletes the mounting bracket, so the unit arrives as a compact, unaccessorised body ready for your own pressure monitoring and fixing arrangement.
| Order code | GTFR20006LJNK |
|---|---|
| Product | Filter Regulator |
| Port | 1/8" (06) |
| Type · gauge | Low-pressure (L) · No gauge (N) |
| Configuration | No bracket (J) · 40 µm element · PT thread · Check valve (K) |
| Port | 1/8" (06), 1/4" (08) |
|---|---|
| Thread | PT (standard) |
| Filter element | 40 µm (standard), 5 µm (W) |
| Bowl | Short PC bowl |
| Drain | Differential + manual |
| Fluid | Air |
| Low-pressure (L) version | 0.15 – 0.4 MPa (20 – 58 psi) |
Source: AirTAC Products Catalog 2026A (p.235, PDF01-P0237), GT200 ordering code and specifications.
The K suffix is the only difference from GTFR20006LJN: same 1/8 in port, same PT thread, same low-pressure 0.15 - 0.4 MPa (20 - 58 psi) range, same 40 um element, same no-gauge and no-bracket configuration. Pick this code if you want downstream retention on supply loss; pick GTFR20006LJNW instead if filtration to 5 um is your priority.
Keeping a low-pressure clamping circuit charged if the upstream feed dips; the check valve holds downstream air while the 0.15 - 0.4 MPa (20 - 58 psi) L range suits delicate parts.
Isolating a 1/8 in PT test line from supply-side pressure decay, with the 40 um element keeping the test air free of coarse contamination.
Supplying compact process equipment that runs below standard shop air, with the short PC bowl and differential plus manual drain keeping condensate under control in tight machine frames.
Port 1/8 in (06) with PT thread; low-pressure L range 0.15 - 0.4 MPa (20 - 58 psi); standard 40 um element; short PC bowl with differential plus manual drain; check valve fitted (K); no gauge (N) and no bracket (J).
Only the check valve: the K code adds one so downstream pressure is retained if the upstream supply drops; everything else in the specification is identical. For the finer 5 um element in this same low-pressure, no-gauge, no-bracket layout, order GTFR20006LJNW.